PC/PPI+:RS232 to PPI optoelectronic isolated adapter for Siemens S7-200 PLC,replace 6ES7 901-3CB30-0XA0
SIMATIC S7-200, PC/PPI CABLE MM MULTIMASTER, FOR CONNECTING S7-200 TO SERIAL PORT OF PC, SUPPORTS FREEPORT AND GSM MODEMS
|
|
Cables | |
belongs to product | SIMATIC S7-200 |
Interfaces | |
Point-to-point | |
Transmission rate (PPI), max. | 187.5 kbit/s; 9.6 / 19.3 / 187.5 kbit/s; setting: DIP switch; RS232 not required |
Protocols | |
PPI | Yes; 10/11 bit |
ASCII | Yes; Freeport |
Interrupts/diagnostics/status information | |
Diagnostics indication LED | |
Description | Tx (green): RS-232-transmit indication; Rx (Grün): RS-232-receive indication; PPI (Green): RS-485-transmit indication |
Galvanic isolation | |
Galvanic isolation | 1 |
Software requirement | |
Software required | STEP 7 Micro/WIN V3.2 SP4 or higher |
Weight | |
Weight, approx. | 300 g |
Status | Mar 11, 2013 |
Our company have the compatible cable, named PC/PPI+, can replace Siemens 6ES7 901-3CB30-0XA0.
You can have a look on the picture.
You can get it only need USD48.00/pc. Buy now ====>
It’s tested before shippment.Not made by Siemens,OEM product as the replacement.
The quality is guaranteed, we have 1 year warranty for our compatible products
Optoelectronic isolated PC/PPI cable,support 10 bit and 11 bit modem communication,with communication indicator,automatically adjust the baud rate from 0 to 115.2Kbps,the largest communication distance of up to 2 kilometers.Not support multi-master station communication.
Specifications:
The OEM Siemens S7-200 PC-PPI+ Programming cable supports full range of Siemens S7-200 PLC programming. It is 100% good replacement for the expensive Simens cable.. It’s tested and proven on S7-212, S7-211, S7-214, S7-224, S7-224XP and it works as a standard Simens serial PC/PPI+ port.
The PC/PPI+ programming cable is the transformation electric cable from RS232 to the PPI connection (RS485), and it is suitable for Simens S7-200 series PLC and the TP170 touchscreen programming, the correspondence and the monitoring. It also supports the PPI agreement and the free mouth communication protocol, and can use MODEM (modem) through the telephone line to make a long-distance correspondence. Since the cable is isolated with the electro-optical and built-in anti-static, surge and other transient over-voltage protection circuit, it solves the problem that the communication I always burned easily well. And it is especially suitable for the long-term monitoring communications which are under the industrial site with a poor environment.
Main technical parameters:
★ Isolation voltage: 1000VDC(The maximum to 3000 VDC, orders required statement)
★ According to a transient voltage suppression. The RS485 port can withstand the power of up to 500 W transient over-voltage and lightning impact,the RS232 port and power circuit are equipped with surge protection to protect the circuit. The whole product can be arbitrarily charged plug.
★ Baud rate:0~115.2kbps Adaptive(products available for sale since January 2008 )
★ The longest communication distance:2 km(Baud rate:9600bps per hour),1km(Baud rate:115.2Kbps per hour)
★ With a power indicator light and the data received and sent indicator light
★ Temperature:-40~85′C(products available for sale since January 2008)
★ Dimension:103×50×26,The total length of cable is 5m.
The product structure:
PPI-RS485 plug |
PC-RS232 plug |
||
Pin |
Signal explanation |
Pin |
Signal explanation |
2 |
24V Power source negative(RS485 Logical place) |
2 |
Receive data RD(Output from PC/PPI) |
3 |
RS485 signal B(RxD/TxD+) |
3 |
Send data SD(Send to PC/PPI) |
7 |
24V Power source positive |
4 |
Data terminal ready DTR |
8 |
RS485 signal A(RxD/TxD-) |
5 |
Ground(RS232 Logical place) |
9 |
Agreement choice |
7 |
Require to send RTS |
Signals of PC-RS232 plugs and PPI-RS485 plugs
The use of products:
1, PLC and computer connections for the PPI or free Communication, programming:
Insert the PC / PPI + cable’s RS485 plug into the programming mouth of S7-200PLC and the RS232 plug into the computer’s RS232 port. Chose the corresponding number of the COM port. Switch the 10bit, 11bit selection switch to 11 bit. The baud rate of the PC/PPI+ cable is adaptive from 0 to 115.2kpbs. There is no need to set that.
2, The long-distance communications between PLC and computer:
When having long-distance communications, the PC / PPI + requires additional external power and we should parallel 120Ωi end resistance n between the 3, 8 of RS485 plugs to eliminate signal reflection, as shown below:
3, long-distance communications between the PLC and computer via telephone lines:
You have to make a cross-adapter by yourself when you get the PC/PPI+’s RS232 port and the MODEM connected. Switch to the corresponding location according to the MODEM that it is 10 or 11.
10 bits MODEM refers: 1 outset bit, 8 data bits, no parity bit, and 1 stop bit(or 7 data bits,1 parity bit).This kind of MODEM is comparative common on the market.
11 bits MODEM refers: 1 outset bit, 8 data bits, 1 parity bit (Occasionally bit check), and 1 stop bit .
If you need non- isolated cable,you can choose our PC/PPI,you can click the following website for PC/PPI:PC-PPI.
Only need USD19.00/pc, you can get it. Buy now ====>
Accessories of Replacements |
Orignal Siemens Model |
---|---|
Profibus BUS Connector(90 without Program interface) |
6ES7972-0BA12-0XA0 |
Profibus BUS Connector(90 with Program interface) |
6ES7972-0BB12-0XA0 |
Profibus BUS Connector(35 without Program interface) |
6ES7972-0BA41-0XA0 |
Profibus BUS Connector(35 with Program interface) |
6ES7972-0BB41-0XA0 |
Profibus BUS Connector |
6ES7 972-0BA50-0XA0 |
Profibus BUS Connector |
6ES7 972-0BB50-0XA0 |
Profibus BUS Connector |
6ES7 972-0BA52-0XA0 |
Profibus BUS Connector |
6GK1500-0FC10 |
Profibus BUS Connector |
6ES7 972-0BB52-0XA0 |
Profibus BUS Connector |
6GK1 500-0EA02 |
Profibus BUS Connector |
6GK1 500-0FC00 |
Profibus BUS Cable |
6XV1 830-0EH10 |
Profibus BUS Cable |
6XV1830-3EH10 |
Profibus BUS Cable |
6XV1840-2AH10 |
20-Pin front Connector |
6ES7392-1AJ00-0AA0 |
40-Pin front Connector |
6ES7392-1AM00-0AA0 |
CP5611 Card |
6GK1561-1AA00 |
CP5611 Card |
6GK1561-1AA01 |
PLC Li-on Battery |
6ES7291-8BA20-OXAO |
PS307 Power supply 5A |
6ES7307-1EA00-0AA0 |
PS307 Power supply 10A |
6ES7307-1KA01-0AA0 |
PS307 Power supply 10A |
6ES7307-1KA02-0AA0 |
DIN Track(830mm) |
6ES7390-1AJ30-0AA0 |
DIN Track(530mm) |
6ES7390-1AF30-0AA0 |
DIN Track(480mm) |
6ES7390-1AE80-0AA0 |
Hot-Plug Track(530mm) |
6ES7390-1GF30-0AA0 |
Recent Comments