May 8 2013

PC/MPI: RS232 Programming adapter for Siemens S7-300 PLC can replace Siemens 6ES7972-0CA23-0XA0

PC/MPI: RS232 Programming adapter for Siemens S7-300 PLC  can replace Siemens 6ES7972-0CA23-0XA0

6ES7972-0CA23-0XA0                     PC-ADAPTER V5.1, RS 232/RS485 CONVERSION
SIMATIC S7, PC ADAPTER V5.1 FOR CONNECTION OF S7-300/400, C7, M7; FOR CONVERSION OF RS232 TO RS485; W/O RS232 CABLE
Below is the data sheet of Siemens  6ES7972-0CA23-0XA0:
SIMATIC S7, PC ADAPTER V5.1 FOR CONNECTION OF S7-300/400, C7, M7; FOR CONVERSION OF RS232 TO RS485; W/O RS232 CABLE
Supply voltage
5 V DC Yes; UN2
24 V DC Yes; UN1
Input current
Current consumption, typ. 90 mA; I1: 50 mA, I2: 40 mA
Inrush current, max. 0.5 A; I1: 0.5 A, 14 ms; I2: 0.2 A, 1.5 ms
1st interface
Type of interface RS 485 (up to max. 1.5 Mbit/s)
2nd interface
Type of interface RS 232 (19.2 kbit/s or 38.4 kbit/s, adjustable by switch)
EMC
Interference immunity against discharge of static electricity
Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 Yes; +/-4 kV contact discharge (to IEC 801-2/IEC 1000-4-2; ESD) +/-8 kV air discharge (to IEC 801-2/IEC 1000-4-2; ESD)
Interference immunity to cable-borne interference
Interference immunity on signal lines acc. to IEC 61000-4-4 Yes; +/- 2 kV (to IEC 801-4/IEC 1000-4-4; Burst)
Immunity against high-frequency electromagnetic fields
Interference immunity against high frequency radiation 10 V/m with 80% amplitude modulation at 1 kHz, 10 kHz to 80 MHz (to ENV 50141); 10 V/m with 80% amplitude modulation at 1 kHz, 80 MHz to 1 GHz (to ENV 50140); 10 V/m pulse modulated 50% ED at 900 MHz (to ENV 50204)
Emission of radio interference acc. to EN 55 022
Interference emission acc. to EN 55022, class B Yes; corresponds to CISPR 22
Degree and class of protection
IP20 Yes
Ambient conditions
Operating temperature
Min. 0 °C
max. 60 °C
Permissible temperature change 10 °C/h; Operation: max. 10°C/h; storage/transport: max. 20°C/h
Storage/transport temperature
Min. -40 °C
max. 70 °C
Relative humidity
Operation, min. 5 %
Operation, max. 85 %; no condensation
Storage/transport, min. 5 %
Storage/transport, max. 93 %; no condensation
Vibrations
Operation, checked according to IEC 60068-2-6 Yes; 10 to 58 Hz: Amplitude 0.075 mm; 58 to 150 Hz: Acceleration 9.8 m/s2
Transport tested checked to IEC 60068-2-6 Yes; (packed) 5 to 9 Hz, amplitude 3.5 mm; 9 to 500 Hz, acceleration 9.8 m/s2
Shock test
checked according to IEC 60068-2-27 Yes; Operation: Half-sine: 100 m/s2 (10 g), 16 ms, transport (packed): Half-sine: 250 m/s2 (25 g), 6 ms
checked according to IEC 60068-2-29 Yes
Dimensions
Width 50 mm
Height 24 mm
Depth 108 mm
Weight
Weight, approx. 150 g
Our company have the compatible cable, named PC/MPI,  can replace Siemens 6ES7972-0CA23-0XA0.
Here, pls have a look on its picture:
PC-MPI
Now, only need USD71.00, you can get it.     Buy now ====> buy buttom
It’s tested before shippment.Not made by Siemens,OEM product as the replacement.The quality is guaranteed, we have 1 year warranty for our compatible products.

The discription of our compatible PC/MPI:

Siemens S7-300 PLC Programming cable,5 meters.

Not isolated,so it doesn’t support hot plug.

PC / MPI adapter is also known as PC adapter. It’s physical interface is the conversion from RS232 interfaces to the RS485,including the conversion from RS232 to MPI protocol (MultiPoint Interface).And it is used for the connecting between the PC COM (RS232) and MPI (RS485) of Siemens S7-300PLC.This product is non-isolate, choose PC / MPI + if you need an electro-optical isolation.

Main technical parameters:

★ RS232 Port baud rate:19.2Kbps

★ MPI Port baud rate:187.5Kbps

★ With the data received and sent indicator light

★ Temperature:0~75℃

★ Total length of cable:5m

STEP7 Software settings:

1、 Go into STEP7 the main software programming interface(SIMATIC Manager),click “Set PG/PC Interface…” which is under the “Options” menu, and the get to the PG/PC setting interface。

2、 Double-click on “PC Adapter(Auto)”or“PC Adapter(MPI)”to go into the interface setting of parameters of RS232 and the MPI. The adapter does not support “PC Adapter (PROFIBUS)” option.

3、 Click on the “Local Connection” option to set the interface parameters of RS232, to choose the right computers COM mouth (RS232), change the RS232 communication baud rate to 19200 bps.

4、 Click the “MPI” option (if it’s on “PC Adapter (MPI)” method) to set MPI interface parameters for the adapter, as the MPI interface of the adapter gets the baud rate fixed at 187.5 Kbps, so here can only be set to 187.5 Kbps.
If it is “PC Adapter (Auto)” method the choice should be “Address: 0″ and “Timeout: 30s”.

After the settings above the adapter can be set up on-line communication with the PLC, now you should pay attention to that you shouldn’t change the factory default of the MPI port baud rate 187.5Kpbs on the CPU which is under the “Network Settings”.

Since the baud rate of the MPI port of the adapter is fixed at 187.5Kbps, if it is set at other figures, the adapter will not work with PLC! Make sure that the baud rate of the MPI port on your S7-300PLC’s CPU is fixed at 187.5Kpbs.Otherwise,you have to use the Siemens’s programming communication facility to set that baud rate to 187.5Kpbs,in order to make the adapter work correctly.
The quality is guaranteed.It’s tested before shippment.Not made by Siemens,OEM product as the replacement.

 

Please feel free to contact me if you have any question.

 