PC/MPI Siemens 6ES7972-0CA23-0XA0

Introduction to OEM Siemens PC/MPI

PC / MPI adapter is also known as PC adapter. It’s physical interface is the conversion from RS232 interfaces to the RS485,including the conversion from RS232 to MPI protocol (MultiPoint Interface).And it is used for the connecting between the PC COM (RS232) and MPI (RS485) of Siemens S7-300PLC.This product is non-isolate, choose PC / MPI + if you need an electro-optical isolation.


Not isolated,so it doesn't support hot plug,if need isolated cable,pls choose PC/MPI+,you can click the following website for PC/MPI+:

PC/MPI+

Main technical parameters:

★ RS232 Port baud rate:19.2Kbps

★ MPI Port baud rate:187.5Kbps

★ With the data received and sent indicator light

★ Temperature:0~75℃

★ Total length of cable:5m

STEP7 Software settings:

1、 Go into STEP7 the main software programming interface(SIMATIC Manager),click “Set PG/PC Interface…” which is under the “Options” menu, and the get to the PG/PC setting interface。

2、 Double-click on “PC Adapter(Auto)”or“PC Adapter(MPI)”to go into the interface setting of parameters of RS232 and the MPI. The adapter does not support "PC Adapter (PROFIBUS)" option.

3、 Click on the "Local Connection" option to set the interface parameters of RS232, to choose the right computers COM mouth (RS232), change the RS232 communication baud rate to 19200 bps.

4、 Click the "MPI" option (if it's on "PC Adapter (MPI)" method) to set MPI interface parameters for the adapter, as the MPI interface of the adapter gets the baud rate fixed at 187.5 Kbps, so here can only be set to 187.5 Kbps.
If it is "PC Adapter (Auto)" method the choice should be "Address: 0" and "Timeout: 30s".

After the settings above the adapter can be set up on-line communication with the PLC, now you should pay attention to that you shouldn’t change the factory default of the MPI port baud rate 187.5Kpbs on the CPU which is under the “Network Settings”.

Since the baud rate of the MPI port of the adapter is fixed at 187.5Kbps, if it is set at other figures, the adapter will not work with PLC! Make sure that the baud rate of the MPI port on your S7-300PLC’s CPU is fixed at 187.5Kpbs.Otherwise,you have to use the Siemens's programming communication facility to set that baud rate to 187.5Kpbs,in order to make the adapter work correctly.


The quality is guaranteed.It's tested before shippment.Not made by Siemens,OEM product as the replacement.

 

 

Part#: PC/MPI

Unit price:USD71.00/pc  buy buttom

 PC-MPI-small

 

More compatible PLC Programming cables of Siemens

CP5611

CP5611-A2

CP5512

CP5512EXP-NEW

PC Adapter CN-NEW

ES-ETH-PPI-NEW

ETH Adapter CN-NEW

USB/PPIM+

PC/PPI

PC/PPI+

USB/MPI+ V4.0

USB/MPI+ V2.0

PC/MPI+ including RS232 cable

PC/MPI

LOGO!USB-CABLE

LOGO!PC-CABLE

MPI extension cable

PC/TTY

 

 

Here, more pictures of our compatible cables of Siemens parts

CP5512_1 CP5611-A2_1 CP5512E_1 logo-usb cable_1 logo-PC cable_1 PC-TTY_1

 

Of course, we also supply some other brands compatible PLC Programming cables, such as Mitsubishi/OMRON/Panasonic/GE/Fuji/Schneider/Allen-Bradley/Delta/Proface…

ES-ETH-SC09-NEW

FX-USB-AW

USB-SC09

USB-SC09-FX

SC-09+

SC-10

USB-QC30R2

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

1747-PIC

1747-UIC

1747-CP3

USB-1747-CP3 

1761-CBL-PM02

USB-1761-CBL-PM02

 

Pictures for your reference:

USB-CN226 _1 USB-CIF02_1 TSXPCX3030_1 IC690USB901_1 IC690ACC901_1 USB-1761-CBL-PM02_1 1747-PIC_1 1747-UIC_1 USB-SC09_1 USB-QC30R2 1 ES-ETH-SC09 1 USB-SC09-FX_1 FX-USB-AW 1

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com