Oct 11 2013

USB-QC30R2 Mitsubishi adapter cable

Introduction to USB-QC30R2

USB-QC30R2 is the programming cable in which USB interface provides both the serial connection and RS232 signal conversion. Under the control of computer-driven driver, the programming cable makes it possible for the computer's USB interface to simulate the traditional serial (known as COM interface), thus various existing programming software such as communications software, monitoring software and other applications can be normally used. The working power supply of this cable is directly from the USB port, but not the PLC programming interface. The two-color LED on the converter box indicates data’s transceiving status.
USB-QC30R2 is applicable to Mitsubishi Q series PLC (Q mode)


USB-QC30R2 principle and figure structure:

5

 

USB-QC30R2 programming cable simulate USB port as traditional serial port (usually COM3), which enables existing programming software(GX Developer) to communicate through simulated traditional port and PLC devices.

 

Functions of USB-QC30R2
● Support USB-QC30R2 programming software version: GPP V4.0, GX Developer V7.0 and above.
● Fully compatible with USB V1.1 norms and USB CDC V1.1
● USB-bus powered, with current consumption of 50 mA
● Baud rate: 300 bps ~ 1Mbps automatically adapt to the standard baud rate
● Support UART data format: data bits: 7-8; stop bit: 1, 2; check-bit: odd / even / no parity
● Each PC only supports one USB cable programming
● Working temperature: -20 ~ +75 'C
●  Color: black

 

Setting of GX Developer
Please set the driver procedure according to the following steps:
1. Turning on PC power that will connect the USB programming cable and make sure the USB port working well.
2. Put the USB programming cable into USB port and Windows will detect the device and help to add new hardware and jump to new device setting. Insert the driver CD and click “next” to continue, or select the driver on the hard disk.
If Windows does not show “find new hardware”, please click “Universal Serial Main Cable controllers” in the hardware list of device manager, and choose the USB device with question mark. Click the right key of mouse and operate to update driver procedure.

If insert the driver CD,you should select the recommended item and click “Next”.

 

If the driver is saved on the hard disk, you should select the second item and click “Next”. You can find the driver on the “USB Drivers1” folder.

3. Windows will detect the setting information, and load the driver to install.

4. Continue to set up, copy the driver procedure files to your hard disk by Windows.

5. When Windows appears “Completing the Found New Hardware Wizard”, click “finish” to end setting up.
6. After setting up, please make sure the "Ports (COM and LPT)" of "Start \ Settings \ Control Panel \ system \ hardware \ Device Manager" appears "USB Serial Port(COMx)". This COMx is the COM port of the USB programming cable. From then on, as long as you insert the programming cable, the COM port will appear. You just have to choose this COM port in application software such as programming software or communication software.

How to change COM setting
1. Delete the driver procedure of all USB to UART products to discharge COM port source, and reset up USB programming cable driver procedure. The device manager will display the cable address COM3.
2. In Windows 2000/XP the COM slogan can be changed directly. Please double click COM port device that is need changing in the device manager, and the device attribute information window will appear. Choose “port setting” as the picture shows. Click "Advanced" button, and the advanced setting information window will appear. Set the COM port to the serial number you want and click "OK" button to complete.

Setting of GX Developer
After completing Driver installation, the corresponding COM port for the USB-QC30R2 programming cable will be displayed in the “Device Manager” of Window. The step next is just to choose this COM port in the programming software and other application software and keep other communication parameters as in the Default settings. And the following steps are exactly the same as in the traditional programming cables with RS232 interfaces.
Open the main windows form(GX Developer), choose “Online” menu then click “Transfer Setup…” and will appear “Transfer Setup” window.
Click “Serial” button of the PC side I/F, and choice the COM X interface as it in the Device Manager.

 

 

About Long Distance Communication
USB-QC30R2 doesn’t support long distance communication.

Notes and Troubleshoot:
1. If the USB programming cable could not be detected when opening the PC, or some other outstanding issues occur, please replug it again.
2.USB to UART is plug and play USB device. When data are being transmitted, please don’t disconnect it.
3.Sometimes when Windows System failures or outstanding issues when plug or unplug the USB cable occur, please restart the computer and PLC.

 

 

Part#: USB-QC30R2

Unit price:USD39.00/pc  buy buttom

 USB-QC30R2-small

More compatible Mitsubishi cable & communication board

ES-ETH-SC09-NEW

FX-USB-AW

USB-SC09

USB-SC09-FX

SC-09+

SC-10

USB-QC30R2

FX2N-485-BD+

FX2N-485-BD

FX2N-422-BD

FX2N-232-BD

FX1N-485-BD

FX1N-422-BD

FX3U-485-BD

FX3U-422-BD

FX3U-232-BD

FX3U-USB-BD

FX2N-4DA

 

Pictures for your reference:

USB-SC09-FX_1 ES-ETH-SC09 1 USB-QC30R2 1 USB-SC09_1

 

Of course, we also can supply some compatible PLC Programming cables of ohter brands, such as Siemens/OMRON/Panasonic/GE/Fuji/Schneider/Allen-Bradley/Delta/Proface…

CP5611

CP5611-A2

CP5512

CP5512EXP-NEW

PC Adapter CN-NEW

ES-ETH-PPI-NEW

ETH Adapter CN-NEW

USB/PPIM+

PC/PPI

PC/PPI+

USB/MPI+ V4.0

USB/MPI+ V2.0

PC/MPI+ including RS232 cable

PC/MPI

LOGO!USB-CABLE

LOGO!PC-CABLE

MPI extension cable

PC/TTY

1747-PIC

1747-UIC

1747-CP3

USB-1747-CP3 

1761-CBL-PM02

USB-1761-CBL-PM02

 

More pictures:

USB-MPI V5.0_1 USB-MPI+V4.0_1 USB-MPI+V2.0_1 logo-PC cable_1 logo-usb cable_1 CP5512E_1 CP5611-A2_1 CP5512_1 PC-TTY_1 1747-UIC_1 0CB20-1 V6.0_1 1747-PIC_1 USB-1761-CBL-PM02_1 IC690ACC901_1 IC690USB901_1 TSXPCX3030_1 USB-CIF02_1 USB-CN226 _1

 

Please feel free to contact me for any question!

Contact person: Miss Nancy

Skype: kollewin
E-mail: nancy@kollewin.com
Tel: +86-0755-26898905-8006
Website: www.kollewin.com

Leave a Reply