May 22
2013
SIEMENS SIMATIC SM7-300 DIGITAL MODULE SM323 6ES7 323-1BL00-0AA0 16DI 24V DC/ 16DO 24V DC
SIEMENS SIMATIC SM7-300 DIGITAL MODULE SM323 6ES7 323-1BL00-0AA0 16DI 24V DC/ 16DO 24V DC
6ES7323-1BL00-0AA0 SM323, 16DI/DO, DC24V, 0,5A
SIMATIC S7-300, DIGITAL MODULE SM 323, OPTICALLY ISOLATED, 16 DI AND 16 DO, 24V DC, 0.5A, AGGREGATE CURRENT 4A, 1X40 PIN
Here, please find below data sheet of Siemens original 6ES7 323-1BL00-0AA0:
|
- |
SIMATIC S7-300, DIGITAL MODULE SM 323, OPTICALLY ISOLATED, 16 DI AND 16 DO, 24V DC, 0.5A, AGGREGATE CURRENT 4A, 1X40 PIN
|
|
| Supply voltage |
| Load voltage L+ |
| Rated value (DC) |
24 V |
| permissible range, lower limit (DC) |
20.4 V |
| permissible range, upper limit (DC) |
28.8 V |
| Input current |
| from load voltage L+ (without load), max. |
80 mA |
| from backplane bus 5 V DC, max. |
80 mA |
| Power losses |
| Power loss, typ. |
6.5 W |
| Digital inputs |
| Number/binary inputs |
16 |
| Input characteristic curve acc. to IEC 61131, Type 1 |
Yes |
| Number of simultaneously controllable inputs |
| all mounting positions |
| up to 40 °C, max. |
16 |
| up to 60 °C, max. |
8 |
| Input voltage |
| Type of input voltage |
DC |
| Rated value, DC |
24 V |
| for signal “0″ |
-30 to +5 V |
| for signal “1″ |
13 to 30 V |
| Input current |
| for signal “1″, typ. |
7 mA |
| Input delay (for rated value of input voltage) |
| for standard inputs |
| at “0″ to “1″, min. |
1.2 ms |
| at “0″ to “1″, max. |
4.8 ms |
| at “1″ to “0″, min. |
1.2 ms |
| at “1″ to “0″, max. |
4.8 ms |
| Cable length |
| Cable length, shielded, max. |
1000 m |
| Cable length unshielded, max. |
600 m |
| Digital outputs |
| Number/binary outputs |
16 |
| Functionality/short-circuit strength |
Yes; Electronic |
| Response threshold, typ. |
1 A |
| Limitation of inductive shutdown voltage to |
L+ (-48 V) |
| Lamp load, max. |
5 W |
| Controlling a digital input |
Yes |
| Load resistance range |
| lower limit |
48 Ω |
| upper limit |
4 kΩ |
| Output voltage |
| for signal “1″, min. |
L+ (-0.8 V) |
| Output current |
| for signal “1″ rated value |
0.5 A |
| for signal “1″ permissible range for 0 to 60 °C, min. |
5 mA |
| for signal “1″ permissible range for 0 to 60 °C, max. |
0.6 A |
| for signal “1″ minimum load current |
5 mA |
| for signal “0″ residual current, max. |
0.5 mA |
| Output delay with resistive load |
| “0″ to “1″, max. |
100 µs |
| “1″ to “0″, max. |
500 µs |
| Parallel switching of 2 outputs |
| for increased power |
No |
| for redundant control of a load |
Yes; only outputs of the same group |
| Switching frequency |
| with resistive load, max. |
100 Hz |
| with inductive load, max. |
0.5 Hz |
| on lamp load, max. |
100 Hz |
| Aggregate current of outputs (per group) |
| horizontal installation |
| up to 40 °C, max. |
4 A |
| up to 60 °C, max. |
3 A |
| Cable length |
| Cable length, shielded, max. |
1000 m |
| Cable length unshielded, max. |
600 m |
| Encoder |
| Connectable encoders |
| 2-wire sensor |
Yes |
| Permissible quiescent current (2-wire sensor), max. |
1.5 mA |
| Isochronous mode |
| Isochronous operation (application synchronized up to terminal) |
No |
| Interrupts/diagnostics/status information |
| Alarms |
| Alarms |
No |
| Diagnostic messages |
| Diagnostic functions |
No |
| Diagnostics indication LED |
| Status indicator digital output (green) |
Yes |
| Status indicator digital input (green) |
Yes |
| Galvanic isolation |
| Galvanic isolation digital inputs |
| between the channels |
Yes |
| between the channels, in groups of |
16 |
| between the channels and the backplane bus |
Yes; Optocoupler |
| Galvanic isolation digital outputs |
| between the channels |
Yes |
| between the channels, in groups of |
8 |
| between the channels and the backplane bus |
Yes; Optocoupler |
| Permissible potential difference |
| between different circuits |
75 VDC / 60 VAC |
| Isolation |
| Isolation checked with |
500 V DC |
| Connection method |
| required front connector |
40-pin |
| Dimensions |
| Width |
40 mm |
| Height |
125 mm |
| Depth |
120 mm |
| Weight |
| Weight, approx. |
260 g |
Our company have the compatible cable, named 323-1BL00-0AA0, can replace Siemens 6ES7 323-1BL00-0AA0.You can have a look on the picture.
You can get it only need USD247.00/pc. Buy now ====> 
It’s tested before shippment.Not made by Siemens,OEM product as the replacement.
The quality is guaranteed, we have 1 year warranty for our compatible products.
Please find below discription of our compatible OEM 323-1BL00-0AA0:
|
Model
|
SM323
inputs/outputs:16
|
| Product Description |
16DI,24VDC/16DO, 24 VDC; Transistor;Optical isolation with high immunity. |
| Power consumption |
| ·From backplane bus current consumption |
80mA |
| ·Power loss |
6.5W |
| Input Feature |
| Number of digital inputs |
16 |
| Input voltage |
| ·Rate value |
24V DC |
| ·For ”0” signal |
-30~5V DC |
| ·For ”1” signal |
13~30V DC |
| Input current |
7mA |
| Input delay |
| ·From “0” to “1”,Min |
1.2~4.8ms |
| ·From “1” to “0”,Min |
1.2~4.8ms |
| Input type |
NPN |
| Connection of 2-wire BERO sensor |
Yes |
| Permissible quiescent current |
1.5mA |
| Output Feature |
| Number of digital outputs |
16 |
| Short-circuit protection |
Yes,Electronic |
| Inductive cutoff voltage |
L+(-53V) |
| Lamp load.Max |
5W |
| Output voltage:for ”1” signal |
Min:L+(-53V) |
| Output current:for ”1” signal |
0.5A |
| Isolation tested for contact |
| ·Between channels and backplane bus |
Yes |
| ·Per group between channels |
Yes |
| Cable Length (Shielded) |
1,000m |
| Cable Length (unshielded) |
600m |
| The status indicates |
Green LED each channel |
| Front connector |
40-pin |
| Dimensions(W x H x D)(mm) |
40×125×120 |
| Order Number |
323-1BL00-0AA0 |

Please feel free to contact me for any question.
Recent Comments