<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Profibus Connector &#187; Siemens 6 GK1 561-1AA00/6 GK1 561-1AA01 communication card CP5611</title>
	<atom:link href="https://www.profibus-connector.com/tag/siemens-6-gk1-561-1aa006-gk1-561-1aa01-communication-card-cp5611/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.profibus-connector.com</link>
	<description>Profibus DP, Profibus Cable, Profibus Repeater and PLC Automation</description>
	<lastBuildDate>Fri, 25 Oct 2013 08:50:10 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.5.1</generator>
		<item>
		<title>Siemens 6 GK1 561-1AA00/6 GK1 561-1AA01 communication card CP5611</title>
		<link>https://www.profibus-connector.com/siemens-6-gk1-561-1aa006-gk1-561-1aa01-communication-card-cp5611/</link>
		<comments>https://www.profibus-connector.com/siemens-6-gk1-561-1aa006-gk1-561-1aa01-communication-card-cp5611/#comments</comments>
		<pubDate>Sat, 27 Apr 2013 03:09:41 +0000</pubDate>
		<dc:creator>nancy</dc:creator>
				<category><![CDATA[Promotion for Siemens products]]></category>
		<category><![CDATA[Siemens 6 GK1 561-1AA00/6 GK1 561-1AA01 communication card CP5611]]></category>

		<guid isPermaLink="false">http://www.profibus-connector.com/?p=25255</guid>
		<description><![CDATA[Siemens 6 GK1 561-1AA00/6 GK1 561-1AA01 communication card CP5611 We have CP5611, which can replace Siemens original 6 GK1 561-1AA00. Now you can get it only need USD199.00/pc.      Purchase it right now. Here, pls read its manual. CP5611 Card introduction [...]]]></description>
				<content:encoded><![CDATA[<p><strong>Siemens 6 GK1 561-1AA00/6 GK1 561-1AA01 communication card CP5611</strong></p>
<p>We have <a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/siemens-CP5611-6GK1561-1AA00?tracking=nancy" target="_blank"><strong>CP5611</strong></a>, which can replace Siemens original 6 GK1 561-1AA00<strong>.</strong></p>
<p>Now you can get it only need USD199.00/pc.     <strong><a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/siemens-CP5611-6GK1561-1AA00?tracking=nancy" target="_blank"> Purchase it right now</a></strong>.</p>
<p><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5611-1-small.jpg"><img class="alignnone size-full wp-image-25256" alt="CP5611-1-small" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5611-1-small.jpg" width="600" height="395" /></a></p>
<p>Here, pls read its manual. <a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5611-Card-introduction.pdf">CP5611 Card introduction</a></p>
<p>&nbsp;</p>
<p>As you know, Siemens original card 6 GK1 561-1AA00 has been replaced by 6 GK1 561-1AA01<strong><strong>.</strong></strong></p>
<p>Of course, we also have a new product can replace it, it&#8217;s named <a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/6GK1561-1AA01-CP5611-A2-Card-PPI-MPI-ProfibusDP?tracking=nancy" target="_blank"><strong>CP5611-A2</strong></a>.</p>
<p><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5611-A2-S.jpg"><img class="alignnone size-full wp-image-25259" alt="CP5611-A2-S" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5611-A2-S.jpg" width="675" height="567" /></a></p>
<p>The ex-work price is USD259.00/pc, <strong><a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/6GK1561-1AA01-CP5611-A2-Card-PPI-MPI-ProfibusDP?tracking=nancy" target="_blank">purchase it right now</a></strong>.</p>
<p>Here, pls find its manual: <a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/IN_CP5611A2_74.pdf">IN_CP5611A2_74</a></p>
<p>For any question or wholesale purchase, pls contact me:</p>
<p>Contact Person: Miss Nancy<br />
Skype: kollewin<br />
E-mail: nancy@kollewin.com<br />
Tel: +86-0755-26898905-8005<br />
Fax: +86-0755-26898905-8008<br />
Website: www.kollewin.com</p>
<p>&nbsp;</p>
<p><strong>Below is the data sheet of Siemens original 6 GK1 561-1AA01.</strong></p>
<table id="MainTable" width="520" border="0">
<tbody>
<tr>
<td>Product-type designation</td>
<td>CP 5611 A2</td>
</tr>
<tr>
<td>
<table>
<tbody>
<tr>
<td width="100%"><a href="http://www.automation.siemens.com/bilddb/index.asp?objKey=P_IK10_XX_00300" target="_blank"><img alt="CP 5611" width="100%" align="top" /></a></td>
</tr>
</tbody>
</table>
</td>
<td>
<div>COMMUNICATION PROCESSOR CP 5611 A2 PCI-CARD (32 BIT; 3.3/5V;33/ 66 MHZ) FOR CONNECTION TO PG OR PC WITH PCI-BUS TO PROFIBUS OR MPI (NO WIN9X-SUPPORT!) CURRENTLY ONLY 32BIT SUPPORT IN CONNECTION WITH SIMATIC NET V8.2 SW!</div>
</td>
</tr>
<tr>
<td>Transmission rate</td>
<td></td>
</tr>
<tr>
<td>Transmission rate</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>at interface 1 / in accordance with PROFIBUS</li>
</ul>
</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>minimum</li>
</ul>
</td>
<td>9.6 kbit/s</td>
</tr>
<tr>
<td>
<ul>
<li>maximum</li>
</ul>
</td>
<td>12 Mbit/s</td>
</tr>
<tr>
<td>Interfaces</td>
<td></td>
</tr>
<tr>
<td>Number of electrical connections / at interface 1 / in accordance with PROFIBUS</td>
<td>1</td>
</tr>
<tr>
<td>Design of electrical connection / at interface 1 / in accordance with PROFIBUS</td>
<td>9-pin Sub-D socket (RS 485)</td>
</tr>
<tr>
<td>Supply voltage, current consumption, power loss</td>
<td></td>
</tr>
<tr>
<td>Type of voltage</td>
<td>DC</td>
</tr>
<tr>
<td>Supply voltage</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>1 / from backplane bus</li>
</ul>
</td>
<td>5 V</td>
</tr>
<tr>
<td>Relative symmetrical tolerance</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>at 5 V / with DC</li>
</ul>
</td>
<td>5 %</td>
</tr>
<tr>
<td>Consumed current</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>1 / from backplane bus / with DC / maximum</li>
</ul>
</td>
<td>0.5 A</td>
</tr>
<tr>
<td>Resistive loss</td>
<td>2.5 W</td>
</tr>
<tr>
<td>Permitted ambient conditions</td>
<td></td>
</tr>
<tr>
<td>Ambient temperature</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>during operating</li>
</ul>
</td>
<td>5…55 °C</td>
</tr>
<tr>
<td>
<ul>
<li>during storage</li>
</ul>
</td>
<td>-20…+60 °C</td>
</tr>
<tr>
<td>
<ul>
<li>during transport</li>
</ul>
</td>
<td>-20…+60 °C</td>
</tr>
<tr>
<td>Relative humidity</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>at 25 °C / without condensation / during operating / maximum</li>
</ul>
</td>
<td>95 %</td>
</tr>
<tr>
<td>Protection class IP</td>
<td>IP00</td>
</tr>
<tr>
<td>Design, dimensions and weight</td>
<td></td>
</tr>
<tr>
<td>Width</td>
<td>18 mm</td>
</tr>
<tr>
<td>Height</td>
<td>102 mm</td>
</tr>
<tr>
<td>Depth</td>
<td>130 mm</td>
</tr>
<tr>
<td>Net weight</td>
<td>100 g</td>
</tr>
<tr>
<td>Product properties, functions, components / general</td>
<td></td>
</tr>
<tr>
<td>Number of plug-in cards in the same design / can be plugged in / per PC station</td>
<td>1</td>
</tr>
<tr>
<td>Number of modules / note</td>
<td>-</td>
</tr>
<tr>
<td>Number of possible connections / for open communication / by means of SEND/RECEIVE / maximum</td>
<td>50</td>
</tr>
<tr>
<td>Software / for DP master function / required</td>
<td>Yes, SOFTNET-PB DP</td>
</tr>
<tr>
<td>Service / as DP master</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>DPV0</li>
</ul>
</td>
<td>Yes</td>
</tr>
<tr>
<td>
<ul>
<li>DPV1</li>
</ul>
</td>
<td>Yes</td>
</tr>
<tr>
<td>
<ul>
<li>DPV2</li>
</ul>
</td>
<td>No</td>
</tr>
<tr>
<td>Number of DP slaves / on DP master / usable</td>
<td>64</td>
</tr>
<tr>
<td>Amount of data</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the inputs / as DP master / overall</li>
</ul>
</td>
<td>14640 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the outputs / as DP master / overall</li>
</ul>
</td>
<td>14640 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the inputs / per DP slave</li>
</ul>
</td>
<td>244 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the outputs / per DP slave</li>
</ul>
</td>
<td>244 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the diagnostic data / per DP slave</li>
</ul>
</td>
<td>244 byte</td>
</tr>
<tr>
<td>Service / as DP slave</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>DPV0</li>
</ul>
</td>
<td>Yes</td>
</tr>
<tr>
<td>
<ul>
<li>DPV1</li>
</ul>
</td>
<td>No</td>
</tr>
<tr>
<td>Amount of data</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the inputs / as DP slave / overall</li>
</ul>
</td>
<td>122 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the outputs / as DP slave / overall</li>
</ul>
</td>
<td>122 byte</td>
</tr>
<tr>
<td>Number of possible connections / for S7/PG communication / maximum</td>
<td>8</td>
</tr>
<tr>
<td>Number of configurable connections / per PC station</td>
<td>207</td>
</tr>
<tr>
<td>Configuration software / required</td>
<td>NCM PC is included in scope of delivery of the required software product</td>
</tr>
<tr>
<td>Product function / Port diagnostics</td>
<td>Yes</td>
</tr>
<tr>
<td>Standards, specifications, approvals</td>
<td></td>
</tr>
<tr>
<td>Standard</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>for EMC</li>
</ul>
</td>
<td>89/336/EEC</td>
</tr>
<tr>
<td>
<ul>
<li>for safety / of CSA and UL</li>
</ul>
</td>
<td>CAN/CSA C22.2 &amp; UL 60950-1, UL 1950</td>
</tr>
<tr>
<td>
<ul>
<li>for emitted interference</li>
</ul>
</td>
<td>EN 61000-6-3</td>
</tr>
<tr>
<td>
<ul>
<li>for interference immunity</li>
</ul>
</td>
<td>EN 61000-6-2</td>
</tr>
<tr>
<td>Verification of suitability</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>CE mark</li>
</ul>
</td>
<td>Yes</td>
</tr>
<tr>
<td>
<ul>
<li>C-Tick</li>
</ul>
</td>
<td>Yes</td>
</tr>
<tr>
<td>Accessories</td>
<td></td>
</tr>
<tr>
<td>Accessories</td>
<td>optional: MPI cable</td>
</tr>
</tbody>