<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Profibus Connector &#187; Promotion for Siemens products</title>
	<atom:link href="https://www.profibus-connector.com/category/promotion-for-siemens-products/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.profibus-connector.com</link>
	<description>Profibus DP, Profibus Cable, Profibus Repeater and PLC Automation</description>
	<lastBuildDate>Fri, 25 Oct 2013 08:50:10 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.5.1</generator>
		<item>
		<title>SIMATIC S7-200,USB/PPI, USB/PPI+,USB/PPIM+ interface cable 6ES7901-3DB30-0XA0</title>
		<link>https://www.profibus-connector.com/simatic-s7-200usbppi-usbppiusbppim-interface-cable-6es7901-3db30-0xa0/</link>
		<comments>https://www.profibus-connector.com/simatic-s7-200usbppi-usbppiusbppim-interface-cable-6es7901-3db30-0xa0/#comments</comments>
		<pubDate>Mon, 29 Apr 2013 04:47:02 +0000</pubDate>
		<dc:creator>nancy</dc:creator>
				<category><![CDATA[Promotion for Siemens products]]></category>
		<category><![CDATA[SIMATIC S7-200]]></category>
		<category><![CDATA[USB/PPI]]></category>
		<category><![CDATA[USB/PPIM+ interface cable 6ES7901-3DB30-0XA0]]></category>

		<guid isPermaLink="false">http://www.profibus-connector.com/?p=25291</guid>
		<description><![CDATA[SIMATIC S7-200,USB/PPI, USB/PPI+,USB/PPIM+ interface cable 6ES7901-3DB30-0XA0 &#160; SIMATIC S7-200,USB/PPI CABLE MM MULTIMASTER, FOR CONNECTING S7-200 TO USB PORT OF PC, FREEPORT NOT SUPPORTED Now, we have new products named USB/PPI, USB/PPI+,USB/PPIM+, which can replace Siemens original 6ES7901-3DB30-0XA0. The ex-work price [...]]]></description>
				<content:encoded><![CDATA[<p><strong>SIMATIC S7-200,USB/PPI, USB/PPI+,USB/PPIM+ interface cable 6ES7901-3DB30-0XA0</strong></p>
<p>&nbsp;</p>
<p>SIMATIC S7-200,USB/PPI CABLE MM MULTIMASTER, FOR CONNECTING S7-200 TO USB PORT OF PC, FREEPORT NOT SUPPORTED</p>
<p>Now, we have new products named <strong>USB/PPI, USB/PPI+,USB/PPIM+</strong>, which can replace Siemens original 6ES7901-3DB30-0XA0.</p>
<p><strong>The ex-work price of <a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/6ES7901-3DB30-0XA0-S7-200-USB-PPI-CABLE?tracking=nancy" target="_blank">USB/PPI</a> is USD33.00/pc, now, <a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/6ES7901-3DB30-0XA0-S7-200-USB-PPI-CABLE?tracking=nancy" target="_blank">purchase it right now</a>.</strong></p>
<p>Here, please find the manual of : <strong><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-PPI.pdf">USB-PPI</a></strong></p>
<p><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-PPI-Small.jpg"><img class="alignnone size-full wp-image-25295" alt="USB-PPI-Small" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-PPI-Small.jpg" width="500" height="390" /></a></p>
<p>&nbsp;</p>
<p><strong>The ex-work price of <a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/6ES7901-3DB30-0XA0-USB-PPI-Cable-For-Siemens-S7-200?tracking=nancy" target="_blank">USB/PPI+</a> is USD49.00/pc, now, <a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/6ES7901-3DB30-0XA0-USB-PPI-Cable-For-Siemens-S7-200?tracking=nancy" target="_blank">purchase it right now</a>.</strong></p>
<p>Please find manual of USB/PPI+: <strong><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-PPI+.pdf">USB-PPI+</a></strong></p>
<p><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-PPI+-small.jpg"><img class="alignnone size-full wp-image-25296" alt="USB-PPI+-small" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-PPI+-small.jpg" width="446" height="400" /></a></p>
<p>&nbsp;</p>
<p><strong>The ex-work price of <a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/S7-200-PLC-adapter-suport-multi-master-station-6ES7901-3DB30-0XA0?tracking=nancy" target="_blank">USB/PPIM+</a> is USD71.00/pc, now, <a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/S7-200-PLC-adapter-suport-multi-master-station-6ES7901-3DB30-0XA0?tracking=nancy" target="_blank">purchase it right now</a>.</strong></p>
<p><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-PPIM+-SMALL.jpg"><img class="alignnone size-full wp-image-25298" alt="USB-PPIM+-SMALL" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-PPIM+-SMALL.jpg" width="525" height="400" /></a></p>
<p>For any problem or wholesale purchase, please feel free to contact me:</p>
<p><strong>Contact Person: Miss Nancy</strong><br />
<strong>Skype: kollewin</strong><br />
<strong>E-mail: nancy@kollewin.com</strong><br />
<strong>Tel: +86-0755-26898905-8005</strong><br />
<strong>Fax: +86-0755-26898905-8008</strong><br />
<strong>Website: www.kollewin.com</strong></p>
<p>USB/PPI interface,programming cable for Siemens S7-200PLC and TP170 touch panel,3 meters,with communication indicator,can replace 6ES7 901-3DB30-0XA0,the largest communication distance of up to 2 kilometers.Not support multi-master station communication.</p>
<div>Data sheet of Siemens original 6ES7901-3DB30-0XA0.</div>
<table id="MainTable" width="600" border="0" cellspacing="0">
<tbody>
<tr>
<td></td>
<td>
<div>SIMATIC S7-200,USB/PPI CABLE MM MULTIMASTER, FOR CONNECTING S7-200 TO USB PORT OF PC, FREEPORT NOT SUPPORTED</div>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2">Cables</td>
</tr>
<tr>
<td>belongs to product</td>
<td>SIMATIC S7-200</td>
</tr>
<tr>
<td colspan="2">Interfaces</td>
</tr>
<tr>
<td colspan="2">Point-to-point</td>
</tr>
<tr>
<td>Transmission rate (PPI), max.</td>
<td>187.5 kbit/s; 9.6 / 19.2 / 187.5 kbit/s; setting: not necessary</td>
</tr>
<tr>
<td colspan="2">Protocols</td>
</tr>
<tr>
<td>PPI</td>
<td>Yes; 10/11 bit</td>
</tr>
<tr>
<td colspan="2">Interrupts/diagnostics/status information</td>
</tr>
<tr>
<td colspan="2">Diagnostics indication LED</td>
</tr>
<tr>
<td>Description</td>
<td>Tx (green): USB send display; Rx (green): USB receive display; PPI (green): RS-485 send display</td>
</tr>
<tr>
<td colspan="2">Galvanic isolation</td>
</tr>
<tr>
<td>Galvanic isolation</td>
<td>1</td>
</tr>
<tr>
<td colspan="2">Software requirement</td>
</tr>
<tr>
<td>Software required</td>
<td>STEP 7 Micro/WIN V3.2 SP4 or higher</td>
</tr>
<tr>
<td colspan="2">Weight</td>
</tr>
<tr>
<td>Weight, approx.</td>
<td>300 g</td>
</tr>
<tr>
<td>Status</td>
<td>Mar 11, 2013</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>https://www.profibus-connector.com/simatic-s7-200usbppi-usbppiusbppim-interface-cable-6es7901-3db30-0xa0/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Siemens S7-200PLC Ethernet adapter ES-ETH-PPI</title>
		<link>https://www.profibus-connector.com/siemens-s7-200plc-ethernet-adapter-es-eth-ppi/</link>
		<comments>https://www.profibus-connector.com/siemens-s7-200plc-ethernet-adapter-es-eth-ppi/#comments</comments>
		<pubDate>Sun, 28 Apr 2013 03:51:08 +0000</pubDate>
		<dc:creator>nancy</dc:creator>
				<category><![CDATA[Promotion for Siemens products]]></category>
		<category><![CDATA[Siemens S7-200PLC Ethernet adapter ES-ETH-PPI]]></category>

		<guid isPermaLink="false">http://www.profibus-connector.com/?p=25285</guid>
		<description><![CDATA[Siemens S7-200PLC Ethernet adapter: ES-ETH-PPI ES-ETH-PPI Siemens S7-200PLC Ethernet adapter, is used for the communication between Siemens S7-200PLC and Ethernet, Internet or 3G wireless network by the programming interface (RS485 interface) of S7-200 PLC. No need to revise the communication [...]]]></description>
				<content:encoded><![CDATA[<p><strong>Siemens S7-200PLC Ethernet adapter: ES-ETH-PPI</strong></p>
<p><a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/ES-ETH-PPI?tracking=nancy" target="_blank"><strong>ES-ETH-PPI</strong></a></p>
<p>Siemens S7-200PLC Ethernet adapter, is used for the communication between Siemens S7-200PLC and Ethernet, Internet or 3G wireless network by the programming interface (RS485 interface) of S7-200 PLC. No need to revise the communication protocol and software,support Dynamic DNS,user can remote control the PLC by the internet. The RJ45 port,RS485 interface and power supply port are all isolated in order to suit harsh environment in the industrial scene.</p>
<p><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/ES-ETH-PPI.jpg"><img class="alignnone size-full wp-image-25286" alt="ES-ETH-PPI" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/ES-ETH-PPI.jpg" width="500" height="444" /></a></p>
<p><strong>The ex-work price is USD150.00/pc.</strong></p>
<p><strong>Here, buy now====&gt;</strong> <a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/ES-ETH-PPI?tracking=nancy" target="_blank"><img class="alignnone size-full wp-image-25316" alt="buy buttom" src="http://www.profibus-connector.com/wp-content/uploads/2013/05/buy-buttom2.jpg" width="100" height="36" /></a><strong></strong>.</p>
<p>Here, please read its manual. <a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/ES-ETH-PPI-USER-MANUAL.pdf">ES-ETH-PPI USER MANUAL</a></p>
<div id="productDescription">
<p><span style="font-family: arial,helvetica,sans-serif;">Siemens S7-200PLC Ethernet adapter, is used for the communication between Siemens S7-200PLC and Ethernet, Internet or 3G wireless network by the programming interface (RS485 interface) of S7-200 PLC. No need to revise the communication protocol and software,support Dynamic DNS,user can remote control the PLC by the internet. The RJ45 port,RS485 interface and power supply port are all isolated in order to suit harsh environment in the industrial scene.</span></p>
<p><span style="font-family: arial,helvetica,sans-serif;">ES-ETH-PPI is the industrial product which use the Ethernet and Internet or 3G wirelss network to achieve Siemens S7-200PLC networking communication. It integrates many complex network protocols, support TCP Server,TCP Client,UDP Unicast,UDP Multicast etc many modes.It has 10M/100M adaptive Ethernet interface and 10-bit and 11-bit RS485 interface which meets Siemens technical specifications.You only need to go on simple setting and then let the S7-200PLC go on network communication.</span></p>
<p><span style="font-family: arial,helvetica,sans-serif;">The RJ45 port,RS485 interface and power supply port are all isolated in order to suit harsh environment in the industrial situations. Especially the isolated power supply port and each signal pin has anti-static protection and surge protection which can solve the communication port easily damaged problem for Siemens S7-200PLC.<br />
Notice: When ES-ETH-PPI is used to communicate between PC and S7-200 PLC,you need to set the local connection as “Modem connection” in the STEP7 Micro/WIN software.When it’s used to communicate between PLC and PLC,you only can use the free port RS485 communication mode,can’t use Siemens PPI,multi-master PPI or advanced PPI protocol,also MPI and profibus protocol.</span></p>
<p><span style="font-family: arial,helvetica,sans-serif;">◆ High-speed, reliable industry standard, anti-interference design suit for the harsh electromagnetic environment<br />
◆32 bit RISC (NP7 series) ARM7TDMI 55DMIPS<br />
◆ 128KB SRAM，128KB Code + 32KB Boot<br />
◆10M/100M adaptive Ethernet interface<br />
◆Support Siemens technical specifications 10-bit and 11-bit RS485 communication mode<br />
◆Support RS485 data bits 5，6，7，8 settable<br />
◆Support RS485 stop bit 1，1.5，2 settable<br />
◆Support RS485 Parity NONE,ODD,EVEN,MARK,SPACE settable<br />
◆Support RS485 baud rate 110～115200bps standard baud rate settable,not support 187.5Kbps baud rate<br />
◆Support PPI communication of RF modem and free port RS485 communication, not support advanced PPI and multi-master PPI protocol<br />
◆Protocols: TCP,UDP,ARP,IP,ICMP,DHCP,BOOTP,DNS<br />
◆Support Dynamic DNS<br />
◆Working mode can be chose TCP Server、TCP Client、UDP multicast and UDP unicast.<br />
◆Built-in Flash memory, can save the setted parameters<br />
◆Support Windows 95/98/ME/NT/2000/XP/2003/XP/Vista/Win7<br />
◆RJ45 port 1500VDC electromagnetic isolated, RS485 interface 1000VDC electromagnetic isolated, power supply 1000VDC electromagnetic isolated<br />
◆Interface protection: power supply port has the reverse polarity protection and over current protection,RS485 interface has the 500W anti-lightning surge protection and overcurrent protection; all pins and terminals have anti-static protection<br />
◆24V±10% DC power supply from PLC RS485 socket,1W power<br />
◆Dimension: 65mm×51mm×26mm, 35mm standard rail installation<br />
◆Temperature: -40°C to +80°C (-40°F to 176°F)，5% to 95% RH </span></p>
<p><span style="font-family: arial,helvetica,sans-serif;"><strong>ProductContent   </strong><br />
1. ES-ETH-PPI  1PC<br />
2. RJ45 Cable 1 PC,2 M<br />
3. CD 1PC</span></p>
<p>&nbsp;</p>
<p><strong>Any question, please contact us.</strong></p>
</div>
]]></content:encoded>
			<wfw:commentRss>https://www.profibus-connector.com/siemens-s7-200plc-ethernet-adapter-es-eth-ppi/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>PC Adapter CN RS232 to PROFIBUS/MPI adapter</title>
		<link>https://www.profibus-connector.com/pc-adapter-cn-rs232-to-profibusmpi-adapter/</link>
		<comments>https://www.profibus-connector.com/pc-adapter-cn-rs232-to-profibusmpi-adapter/#comments</comments>
		<pubDate>Sun, 28 Apr 2013 03:34:33 +0000</pubDate>
		<dc:creator>nancy</dc:creator>
				<category><![CDATA[Promotion for Siemens products]]></category>
		<category><![CDATA[PC Adapter CN RS232 to PROFIBUS/MPI adapter]]></category>

		<guid isPermaLink="false">http://www.profibus-connector.com/?p=25270</guid>
		<description><![CDATA[PC Adapter CN RS232 to PROFIBUS/MPI adapter PC Adapter CN The ex-work price is USD286.00/pc.   Buy now ====&#62;  It&#8217;s tested before shippment.Not made by Siemens,OEM product as the replacement. The quality is guaranteed, we have 1 year warranty for our [...]]]></description>
				<content:encoded><![CDATA[<p><strong>PC Adapter CN RS232 to PROFIBUS/MPI adapter</strong></p>
<p><a href="http://www.automation-world.com/PC-Adapter-CN?filter_name=PC%20Adapter%20CN?tracking=nancy" target="_blank"><strong>PC Adapter CN</strong></a></p>
<p><strong>The ex-work price is USD286.00/pc.  </strong></p>
<p><strong>Buy now ====&gt;</strong>  <a href="http://www.automation-world.com/PC-Adapter-CN?filter_name=PC%20Adapter%20CN?tracking=nancy" target="_blank"><img class="alignnone size-full wp-image-25316" alt="buy buttom" src="http://www.profibus-connector.com/wp-content/uploads/2013/05/buy-buttom2.jpg" width="100" height="36" /></a></p>
<p>It&#8217;s tested before shippment.Not made by Siemens,OEM product as the replacement.</p>
<p>The quality is guaranteed, we have 1 year warranty for our compatible products.</p>
<p><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/PC-Adapter-CN.jpg"><img class="alignnone size-full wp-image-25272" alt="PC Adapter CN" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/PC-Adapter-CN.jpg" width="618" height="523" /></a></p>
<p>Here, please read its manual: <a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/PC-Adapter-CN-USER-MANUAL.pdf">PC Adapter CN USER MANUAL</a></p>
<p>&nbsp;</p>
<p><strong>Please read below description of our PC Adapter CN:</strong></p>
<p>This adapter is compatible with Siemens PC Adapter and HMI adapter,fully support  RS232 port of PC and HMI to PROFIBUS/MPI communication, use the Siemens special protocol processing chip,it can be used for Siemens S7-300/400 series PLC and other equipments with PROFIBUS/MPI interface. RS232-RS485-power supply are all optical isolated, especially suitable for the strong interference and communication interface easily damaged industrial scene.<br />
PC Adapter CN is a high-tech adapter compatible with Siemens PC Adapter and HMI Adapter,fully support RS232 serial port of PC and HMI to PROFIBUS/MPI communication, adopt the Siemens protocol processor chip,no functional defects. PC Adapter CN is the opto-isolated adapter for industrial design.It has the surge protection and anti-lightning protection circuit on the RS232 interface and RS485 interface, support hot plug, is suitable for Siemens S7-300/400 series PLC and other equipments with PROFIBUS/MPI interface. In particular, it applies to the strong interfere industrial situations and the safeguard in the circuit guarantees the safely running of the system.<br />
PC Adapter CN can communicate between S7-300/400PLC and RS232 interface of third party HMI,can replace the Siemens HMI Adapter.</p>
<p>The low version PC/MPI+ didn’t adopt the Siemens protocol processor chip,but adopt the MCU and use the software to achieve the profibus protocol,the protocol is not perfect and has the defect,only support MPI communication,not support profibus communication,can only connect few HMI and have the defect. When there are many nodes or third-party device in the network,it can’t identify every node. At the same time, it may have the risk that PC/MPI+ can’t be used after the PLC internal program is upgraded in the future.<br />
Main Technical Specifications:</p>
<p>● RS232 interface can connect PC or HMI etc third party devices,baud rate 9.6Kbps～115.2Kbps automatically adjust.<br />
● Support PROFIBUS and MPI communication, auto bus protocol test,largest baud rate 1.5Mbps.<br />
● Power supply from PLC port,24VDC, Power Consumption 2W,with over current and surge protection.<br />
● Power-RS485-RS232 all isolated<br />
● Opto-isolated voltage 1000VDC.<br />
● RS232 interface has the anti-surging protection<br />
● RS485 interface has the anti-lightning and surging protector, Repeatability surge capacity: Ipp=100A(10/700us，4KV),meet the standard ITU-TK20/21、VDE 0433. ±15KV ESD protection.<br />
● Need additional 24VDC power for the long distance communication, the largest cable length meets the profibus standard.<br />
● With the power indicator, data sending indicator, data receiving indicator<br />
Can install the adapter on the S7-300/400PLC rail or 35MM standard rail.<br />
● Shape Size: 123mm×68mm×30mm(Length*Width*Height),with the mounting bracket<br />
● Working Temperature: -20～+75℃</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Pls feel free to contact me if you have any question.</strong></p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>https://www.profibus-connector.com/pc-adapter-cn-rs232-to-profibusmpi-adapter/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Network adapter ETH Adapter CN: Siemens S7-300/400 PLC Ethernet adapter</title>
		<link>https://www.profibus-connector.com/network-adapter-eth-adapter-cn-siemens-s7-300400-plc-ethernet-adapter/</link>
		<comments>https://www.profibus-connector.com/network-adapter-eth-adapter-cn-siemens-s7-300400-plc-ethernet-adapter/#comments</comments>
		<pubDate>Sat, 27 Apr 2013 03:24:05 +0000</pubDate>
		<dc:creator>nancy</dc:creator>
				<category><![CDATA[Promotion for Siemens products]]></category>
		<category><![CDATA[Network adapter ETH Adapter CN: Siemens S7-300/400 PLC Ethernet adapter]]></category>

		<guid isPermaLink="false">http://www.profibus-connector.com/?p=25264</guid>
		<description><![CDATA[Network adapter ETH Adapter CN: Siemens S7-300/400 PLC Ethernet adapter  ETH Adapter CN The ex-work price is USD345.00/pc, . Pls read its munual: ETH Adapter CN USER MANUAL &#160; Siemens S7-300/400PLC Ethernet adapter,is used for the communication between S7-300/400PLC and [...]]]></description>
				<content:encoded><![CDATA[<p><strong>Network adapter ETH Adapter CN: Siemens S7-300/400 PLC Ethernet adapter </strong></p>
<p><a href="http://www.automation-world.com/ETH%20Adapter%20CN?tracking=nancy" target="_blank"><strong>ETH Adapter CN</strong></a></p>
<p>The ex-work price is USD345.00/pc, <a href="http://www.automation-world.com/ETH%20Adapter%20CN?tracking=nancy" target="_blank"><img class="alignnone size-full wp-image-25316" alt="buy buttom" src="http://www.profibus-connector.com/wp-content/uploads/2013/05/buy-buttom2.jpg" width="100" height="36" /></a><strong></strong>.</p>
<p><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/ETH-Adapter-CN.jpg"><img class="alignnone size-full wp-image-25265" alt="ETH Adapter CN" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/ETH-Adapter-CN.jpg" width="500" height="362" /></a></p>
<p>Pls read its munual: <a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/ETH-Adapter-CN-USER-MANUAL.pdf">ETH Adapter CN USER MANUAL</a></p>
<p>&nbsp;</p>
<p>Siemens S7-300/400PLC Ethernet adapter,is used for the communication between S7-300/400PLC and Ethernet,Internet or 3G wireless network by the MPI or DP interface.No need to revise the communication protocol and software, support Dynamic DNS, user can remote control the PLC by the internet. The RJ45 port,RS485 interface and power supply port are all isolated in order to suit harsh environment in the industrial scene.</p>
<p>ETH Adapter CN is the industrial product which use the Ethernet and Internet or 3G wirelss network to achieve Siemens S7-300/400PLC networking communication. It integrates many complex network protocols, support TCP Server,TCP Client,UDP Unicast,UDP Multicast etc many modes.It has 10M/100M adaptive Ethernet interface and MPI and PROFIBUS interface which meets Siemens technical specifications.You only need to go on simple setting and then let the S7-300/400PLC go on network communication.</p>
<p>The RJ45 port,RS485 interface and power supply port are all isolated in order to suit harsh environment in the industrial situations. Especially the isolated power supply port and each signal pin has anti-static protection and surge protection which can solve the PLC communication port easily damaged problem.<br />
◆ High-speed, reliable industry standard, anti-interference design suit for the harsh electromagnetic environment<br />
◆ 32 bit RISC (NP7 series) ARM7TDMI 55DMIPS。<br />
◆ 128KB SRAM,128KB Code + 32KB Boot。<br />
◆10M/100M adaptive Ethernet interface<br />
◆Support MPI and PROFIBUS communication protocol.<br />
◆The largest baud rate is 1.5Mbps for MPI and Profibus interface.<br />
◆Ethernet interface baud rate 9.6Kbps,19.2Kbps,38.4Kbps,57.6Kbps,115.2Kbps can be set.<br />
◆Smart Protocols: TCP,UDP,ARP,IP,ICMP,DHCP,BOOTP,DNS.<br />
◆Support Dynamic DNS<br />
◆Working mode can be chose TCP Server,TCP Client,UDP Multicast and UDP Unicast.<br />
◆Built-in Flash memory,can save the setted parameters<br />
◆Support Windows 95/98/ME/NT/2000/XP/2003/XP/Vista/Win7 operation system.<br />
◆RJ45 port 1500VDC electromagnetic isolated,RS485 interface 1000VDC electromagnetic isolated,power supply 1000VDC electromagnetic isolated<br />
◆Interface protection: power supply port has the reverse polarity protection and over current protection,RS485 interface has the anti-lightning surge protection, repeatability surge capacity: Ipp=100A（10/700us，4KV）,meet standard ITU-TK20/21、VDE 0433. ±15KV ESD protection; overcurrent protection.<br />
◆Power supply 24V±10% DC from PLC MPI or PROFIBUS socket,2W power.<br />
◆Shape Size: 123mm×68mm×30mm(length*width*height),with the mounting bracket.<br />
◆Temperature: -40°C to +80°C (-40°F to 176°F)，5% to 95% RH<br />
◆Storage temperature: -40°C to +80°C (-40°F to 176°F)，5% to 95% RH.</p>
<p>The network type and fieldbus communication baud rate which ETH Adapter CN support</p>
<table border="1" cellspacing="0" cellpadding="0" align="center">
<tbody>
<tr>
<td rowspan="2">
<p align="center">Transmission rate</p>
</td>
<td rowspan="2">
<p align="center">MPI</p>
</td>
<td rowspan="2">
<p align="center">PPI</p>
</td>
<td colspan="3">
<p align="center">PROFIBUS</p>
</td>
</tr>
<tr>
<td>
<p align="center">DP</p>
</td>
<td>
<p align="center">Standard</p>
</td>
<td>
<p align="center">Universal</p>
</td>
</tr>
<tr>
<td>9.6Kbps</td>
<td>
<p align="center">-</p>
</td>
<td>
<p align="center">-</p>
</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">√</p>
</td>
</tr>
<tr>
<td>19.2Kbps</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">-</p>
</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">√</p>
</td>
</tr>
<tr>
<td>45.45Kbps</td>
<td>
<p align="center">-</p>
</td>
<td>
<p align="center">-</p>
</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">√</p>
</td>
</tr>
<tr>
<td>93.75Kbps</td>
<td>
<p align="center">-</p>
</td>
<td>
<p align="center">-</p>
</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">√</p>
</td>
</tr>
<tr>
<td>187.5Kbps</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">-</p>
</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">√</p>
</td>
</tr>
<tr>
<td>500Kbps</td>
<td>
<p align="center">-</p>
</td>
<td>
<p align="center">-</p>
</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">√</p>
</td>
</tr>
<tr>
<td>1.5Mbps</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">-</p>
</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">√</p>
</td>
<td>
<p align="center">√</p>
</td>
</tr>
</tbody>
</table>
<div></div>
<p><strong>Product Content           </strong><br />
1.ETH Adapter CN  1PC<br />
2. RJ45 Cable 1 PC,  2 M<br />
3.CD 1PC</p>
<p>&nbsp;</p>
<p><strong>Please feel free to contact us if you have any problem.</strong></p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>https://www.profibus-connector.com/network-adapter-eth-adapter-cn-siemens-s7-300400-plc-ethernet-adapter/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Siemens 6 GK1 561-1AA00/6 GK1 561-1AA01 communication card CP5611</title>
		<link>https://www.profibus-connector.com/siemens-6-gk1-561-1aa006-gk1-561-1aa01-communication-card-cp5611/</link>
		<comments>https://www.profibus-connector.com/siemens-6-gk1-561-1aa006-gk1-561-1aa01-communication-card-cp5611/#comments</comments>
		<pubDate>Sat, 27 Apr 2013 03:09:41 +0000</pubDate>
		<dc:creator>nancy</dc:creator>
				<category><![CDATA[Promotion for Siemens products]]></category>
		<category><![CDATA[Siemens 6 GK1 561-1AA00/6 GK1 561-1AA01 communication card CP5611]]></category>

		<guid isPermaLink="false">http://www.profibus-connector.com/?p=25255</guid>
		<description><![CDATA[Siemens 6 GK1 561-1AA00/6 GK1 561-1AA01 communication card CP5611 We have CP5611, which can replace Siemens original 6 GK1 561-1AA00. Now you can get it only need USD199.00/pc.      Purchase it right now. Here, pls read its manual. CP5611 Card introduction [...]]]></description>
				<content:encoded><![CDATA[<p><strong>Siemens 6 GK1 561-1AA00/6 GK1 561-1AA01 communication card CP5611</strong></p>
<p>We have <a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/siemens-CP5611-6GK1561-1AA00?tracking=nancy" target="_blank"><strong>CP5611</strong></a>, which can replace Siemens original 6 GK1 561-1AA00<strong>.</strong></p>
<p>Now you can get it only need USD199.00/pc.     <strong><a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/siemens-CP5611-6GK1561-1AA00?tracking=nancy" target="_blank"> Purchase it right now</a></strong>.</p>
<p><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5611-1-small.jpg"><img class="alignnone size-full wp-image-25256" alt="CP5611-1-small" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5611-1-small.jpg" width="600" height="395" /></a></p>
<p>Here, pls read its manual. <a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5611-Card-introduction.pdf">CP5611 Card introduction</a></p>
<p>&nbsp;</p>
<p>As you know, Siemens original card 6 GK1 561-1AA00 has been replaced by 6 GK1 561-1AA01<strong><strong>.</strong></strong></p>
<p>Of course, we also have a new product can replace it, it&#8217;s named <a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/6GK1561-1AA01-CP5611-A2-Card-PPI-MPI-ProfibusDP?tracking=nancy" target="_blank"><strong>CP5611-A2</strong></a>.</p>
<p><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5611-A2-S.jpg"><img class="alignnone size-full wp-image-25259" alt="CP5611-A2-S" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5611-A2-S.jpg" width="675" height="567" /></a></p>
<p>The ex-work price is USD259.00/pc, <strong><a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/6GK1561-1AA01-CP5611-A2-Card-PPI-MPI-ProfibusDP?tracking=nancy" target="_blank">purchase it right now</a></strong>.</p>
<p>Here, pls find its manual: <a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/IN_CP5611A2_74.pdf">IN_CP5611A2_74</a></p>
<p>For any question or wholesale purchase, pls contact me:</p>
<p>Contact Person: Miss Nancy<br />
Skype: kollewin<br />
E-mail: nancy@kollewin.com<br />
Tel: +86-0755-26898905-8005<br />
Fax: +86-0755-26898905-8008<br />
Website: www.kollewin.com</p>
<p>&nbsp;</p>
<p><strong>Below is the data sheet of Siemens original 6 GK1 561-1AA01.</strong></p>
<table id="MainTable" width="520" border="0">
<tbody>
<tr>
<td>Product-type designation</td>
<td>CP 5611 A2</td>
</tr>
<tr>
<td>
<table>
<tbody>
<tr>
<td width="100%"><a href="http://www.automation.siemens.com/bilddb/index.asp?objKey=P_IK10_XX_00300" target="_blank"><img alt="CP 5611" width="100%" align="top" /></a></td>
</tr>
</tbody>
</table>
</td>
<td>
<div>COMMUNICATION PROCESSOR CP 5611 A2 PCI-CARD (32 BIT; 3.3/5V;33/ 66 MHZ) FOR CONNECTION TO PG OR PC WITH PCI-BUS TO PROFIBUS OR MPI (NO WIN9X-SUPPORT!) CURRENTLY ONLY 32BIT SUPPORT IN CONNECTION WITH SIMATIC NET V8.2 SW!</div>
</td>
</tr>
<tr>
<td>Transmission rate</td>
<td></td>
</tr>
<tr>
<td>Transmission rate</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>at interface 1 / in accordance with PROFIBUS</li>
</ul>
</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>minimum</li>
</ul>
</td>
<td>9.6 kbit/s</td>
</tr>
<tr>
<td>
<ul>
<li>maximum</li>
</ul>
</td>
<td>12 Mbit/s</td>
</tr>
<tr>
<td>Interfaces</td>
<td></td>
</tr>
<tr>
<td>Number of electrical connections / at interface 1 / in accordance with PROFIBUS</td>
<td>1</td>
</tr>
<tr>
<td>Design of electrical connection / at interface 1 / in accordance with PROFIBUS</td>
<td>9-pin Sub-D socket (RS 485)</td>
</tr>
<tr>
<td>Supply voltage, current consumption, power loss</td>
<td></td>
</tr>
<tr>
<td>Type of voltage</td>
<td>DC</td>
</tr>
<tr>
<td>Supply voltage</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>1 / from backplane bus</li>
</ul>
</td>
<td>5 V</td>
</tr>
<tr>
<td>Relative symmetrical tolerance</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>at 5 V / with DC</li>
</ul>
</td>
<td>5 %</td>
</tr>
<tr>
<td>Consumed current</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>1 / from backplane bus / with DC / maximum</li>
</ul>
</td>
<td>0.5 A</td>
</tr>
<tr>
<td>Resistive loss</td>
<td>2.5 W</td>
</tr>
<tr>
<td>Permitted ambient conditions</td>
<td></td>
</tr>
<tr>
<td>Ambient temperature</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>during operating</li>
</ul>
</td>
<td>5…55 °C</td>
</tr>
<tr>
<td>
<ul>
<li>during storage</li>
</ul>
</td>
<td>-20…+60 °C</td>
</tr>
<tr>
<td>
<ul>
<li>during transport</li>
</ul>
</td>
<td>-20…+60 °C</td>
</tr>
<tr>
<td>Relative humidity</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>at 25 °C / without condensation / during operating / maximum</li>
</ul>
</td>
<td>95 %</td>
</tr>
<tr>
<td>Protection class IP</td>
<td>IP00</td>
</tr>
<tr>
<td>Design, dimensions and weight</td>
<td></td>
</tr>
<tr>
<td>Width</td>
<td>18 mm</td>
</tr>
<tr>
<td>Height</td>
<td>102 mm</td>
</tr>
<tr>
<td>Depth</td>
<td>130 mm</td>
</tr>
<tr>
<td>Net weight</td>
<td>100 g</td>
</tr>
<tr>
<td>Product properties, functions, components / general</td>
<td></td>
</tr>
<tr>
<td>Number of plug-in cards in the same design / can be plugged in / per PC station</td>
<td>1</td>
</tr>
<tr>
<td>Number of modules / note</td>
<td>-</td>
</tr>
<tr>
<td>Number of possible connections / for open communication / by means of SEND/RECEIVE / maximum</td>
<td>50</td>
</tr>
<tr>
<td>Software / for DP master function / required</td>
<td>Yes, SOFTNET-PB DP</td>
</tr>
<tr>
<td>Service / as DP master</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>DPV0</li>
</ul>
</td>
<td>Yes</td>
</tr>
<tr>
<td>
<ul>
<li>DPV1</li>
</ul>
</td>
<td>Yes</td>
</tr>
<tr>
<td>
<ul>
<li>DPV2</li>
</ul>
</td>
<td>No</td>
</tr>
<tr>
<td>Number of DP slaves / on DP master / usable</td>
<td>64</td>
</tr>
<tr>
<td>Amount of data</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the inputs / as DP master / overall</li>
</ul>
</td>
<td>14640 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the outputs / as DP master / overall</li>
</ul>
</td>
<td>14640 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the inputs / per DP slave</li>
</ul>
</td>
<td>244 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the outputs / per DP slave</li>
</ul>
</td>
<td>244 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the diagnostic data / per DP slave</li>
</ul>
</td>
<td>244 byte</td>
</tr>
<tr>
<td>Service / as DP slave</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>DPV0</li>
</ul>
</td>
<td>Yes</td>
</tr>
<tr>
<td>
<ul>
<li>DPV1</li>
</ul>
</td>
<td>No</td>
</tr>
<tr>
<td>Amount of data</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the inputs / as DP slave / overall</li>
</ul>
</td>
<td>122 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the outputs / as DP slave / overall</li>
</ul>
</td>
<td>122 byte</td>
</tr>
<tr>
<td>Number of possible connections / for S7/PG communication / maximum</td>
<td>8</td>
</tr>
<tr>
<td>Number of configurable connections / per PC station</td>
<td>207</td>
</tr>
<tr>
<td>Configuration software / required</td>
<td>NCM PC is included in scope of delivery of the required software product</td>
</tr>
<tr>
<td>Product function / Port diagnostics</td>
<td>Yes</td>
</tr>
<tr>
<td>Standards, specifications, approvals</td>
<td></td>
</tr>
<tr>
<td>Standard</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>for EMC</li>
</ul>
</td>
<td>89/336/EEC</td>
</tr>
<tr>
<td>
<ul>
<li>for safety / of CSA and UL</li>
</ul>
</td>
<td>CAN/CSA C22.2 &amp; UL 60950-1, UL 1950</td>
</tr>
<tr>
<td>
<ul>
<li>for emitted interference</li>
</ul>
</td>
<td>EN 61000-6-3</td>
</tr>
<tr>
<td>
<ul>
<li>for interference immunity</li>
</ul>
</td>
<td>EN 61000-6-2</td>
</tr>
<tr>
<td>Verification of suitability</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>CE mark</li>
</ul>
</td>
<td>Yes</td>
</tr>
<tr>
<td>
<ul>
<li>C-Tick</li>
</ul>
</td>
<td>Yes</td>
</tr>
<tr>
<td>Accessories</td>
<td></td>
</tr>
<tr>
<td>Accessories</td>
<td>optional: MPI cable</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>https://www.profibus-connector.com/siemens-6-gk1-561-1aa006-gk1-561-1aa01-communication-card-cp5611/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Laptop cards Cardbus pc  card pcmcia   Siemens cp 5512</title>
		<link>https://www.profibus-connector.com/usb-mpi-cables/</link>
		<comments>https://www.profibus-connector.com/usb-mpi-cables/#comments</comments>
		<pubDate>Wed, 24 Apr 2013 03:54:06 +0000</pubDate>
		<dc:creator>Tiny</dc:creator>
				<category><![CDATA[Promotion for Siemens products]]></category>
		<category><![CDATA[Laptop cards Cardbus pc card pcmcia Siemens cp 5512]]></category>

		<guid isPermaLink="false">http://www.profibus-connector.com/?p=25195</guid>
		<description><![CDATA[Laptop cards Cardbus pc  card pcmcia   Siemens cp 5512 6GK1551-2AA00 Here, we have a new part named CP5512, can replace Siemens 6GK1551-2AA00. Now, you can get it only by USD361.00/pc.  Puchase it right now. Here, pls check the manual of [...]]]></description>
				<content:encoded><![CDATA[<p><strong>Laptop cards Cardbus pc  card pcmcia   Siemens<a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/cp5512-6GK1551-2AA00-ppi-mpi-profibus-dp-card" target="_blank"> cp 5512 </a></strong></p>
<div>6GK1551-2AA00</div>
<div></div>
<div>Here, we have a new part named <a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/cp5512-6GK1551-2AA00-ppi-mpi-profibus-dp-card?tracking=nancy" target="_blank"><strong>CP5512</strong></a>, can replace Siemens 6GK1551-2AA00.</div>
<div><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5512-3.jpg"><img class="alignnone size-full wp-image-25252" alt="CP5512-3" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5512-3.jpg" width="600" height="331" /></a></div>
<div>Now, you can get it only by USD361.00/pc.  <strong><a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/cp5512-6GK1551-2AA00-ppi-mpi-profibus-dp-card?tracking=nancy" target="_blank">Puchase it right now.</a></strong></div>
<div>Here, pls check the manual of our compatible CP5512 card:</div>
<div><strong><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5512-introduction1.pdf">CP5512 introduction</a></strong></div>
<div></div>
<div>We also have a new product named<a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/cp5512-express-card-ppi-mpi-profibus-dp-s7-200-300-400?tracking=nancy" target="_blank"> <strong>CP-5512-Express card</strong>.</a></div>
<div><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5512-Expresscard-s.jpg"><img class="alignnone size-full wp-image-25253" alt="CP5512 Expresscard-s" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5512-Expresscard-s.jpg" width="800" height="600" /></a></div>
<div>The ex-work price is USD. <strong><a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/cp5512-express-card-ppi-mpi-profibus-dp-s7-200-300-400?tracking=nancy" target="_blank">Purchase it right now</a>.</strong></div>
<div>Here, its manual:</div>
<div><strong><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/CP5512-Express-Intro.pdf">CP5512 Express Intro</a></strong></div>
<div></div>
<div>For more details or wholesale purchase, pls contact me by below information:</div>
<div>Contact person: Miss Nancy<br />
Skype:  kollewin<br />
E-mail: nancy@kollewin.com<br />
Tel: +86-0755-26898905-8005<br />
Fax: +86-0755-26898905-8008<br />
Website: www.kollewin.com</div>
<div></div>
<div>Below is the data sheet of Siemens original 6GK1551-2AA00:</div>
<div></div>
<div>
<table id="MainTable" width="520" border="0">
<tbody>
<tr>
<td>Product-type designation</td>
<td>CP 5512</td>
</tr>
<tr>
<td>
<table>
<tbody>
<tr>
<td width="100%"><a href="http://www.automation.siemens.com/bilddb/index.asp?objKey=P_IK10_XX_00118" target="_blank"><img alt="CP 5512 communications processor" width="100%" align="top" /></a></td>
</tr>
</tbody>
</table>
</td>
<td>
<div>COMMUNICATION PROCESSOR CP 5512 PC CARD (CARDBUS, 32 BITS) FOR CONNECTION OF A PG OR NOTEBOOK TO PROFIBUS OR MPI</div>
</td>
</tr>
<tr>
<td>Transmission rate</td>
<td></td>
</tr>
<tr>
<td>Transmission rate</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>at interface 1 / in accordance with PROFIBUS</li>
</ul>
</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>minimum</li>
</ul>
</td>
<td>9.6 kbit/s</td>
</tr>
<tr>
<td>
<ul>
<li>maximum</li>
</ul>
</td>
<td>12 Mbit/s</td>
</tr>
<tr>
<td>Interfaces</td>
<td></td>
</tr>
<tr>
<td>Number of electrical connections / at interface 1 / in accordance with PROFIBUS</td>
<td>1</td>
</tr>
<tr>
<td>Design of electrical connection / at interface 1 / in accordance with PROFIBUS</td>
<td>9-pin Sub-D socket (RS 485)</td>
</tr>
<tr>
<td>Supply voltage, current consumption, power loss</td>
<td></td>
</tr>
<tr>
<td>Type of voltage</td>
<td>DC</td>
</tr>
<tr>
<td>Supply voltage</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>1 / from backplane bus</li>
</ul>
</td>
<td>3.3 V</td>
</tr>
<tr>
<td>Relative symmetrical tolerance</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>at 3.3 V / with DC</li>
</ul>
</td>
<td>5 %</td>
</tr>
<tr>
<td>Consumed current</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>1 / from backplane bus / with DC / maximum</li>
</ul>
</td>
<td>0.52 A</td>
</tr>
<tr>
<td>Resistive loss</td>
<td>1.8 W</td>
</tr>
<tr>
<td>Permitted ambient conditions</td>
<td></td>
</tr>
<tr>
<td>Ambient temperature</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>during operating</li>
</ul>
</td>
<td>5…45 °C</td>
</tr>
<tr>
<td>
<ul>
<li>during storage</li>
</ul>
</td>
<td>-20…+60 °C</td>
</tr>
<tr>
<td>
<ul>
<li>during transport</li>
</ul>
</td>
<td>-20…+60 °C</td>
</tr>
<tr>
<td>Relative humidity</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>at 25 °C / without condensation / during operating / maximum</li>
</ul>
</td>
<td>95 %</td>
</tr>
<tr>
<td>Protection class IP</td>
<td>IP00</td>
</tr>
<tr>
<td>Design, dimensions and weight</td>
<td></td>
</tr>
<tr>
<td>Width</td>
<td>86 mm</td>
</tr>
<tr>
<td>Height</td>
<td>5 mm</td>
</tr>
<tr>
<td>Depth</td>
<td>54 mm</td>
</tr>
<tr>
<td>Net weight</td>
<td>130 g</td>
</tr>
<tr>
<td>Product properties, functions, components / general</td>
<td></td>
</tr>
<tr>
<td>Number of plug-in cards in the same design / can be plugged in / per PC station</td>
<td>1</td>
</tr>
<tr>
<td>Number of modules / note</td>
<td>-</td>
</tr>
<tr>
<td>Number of possible connections / for open communication / by means of SEND/RECEIVE / maximum</td>
<td>50</td>
</tr>
<tr>
<td>Software / for DP master function / required</td>
<td>Yes, SOFTNET-PB DP</td>
</tr>
<tr>
<td>Service / as DP master</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>DPV0</li>
</ul>
</td>
<td>Yes</td>
</tr>
<tr>
<td>
<ul>
<li>DPV1</li>
</ul>
</td>
<td>No</td>
</tr>
<tr>
<td>
<ul>
<li>DPV2</li>
</ul>
</td>
<td>No</td>
</tr>
<tr>
<td>Number of DP slaves / on DP master / usable</td>
<td>64</td>
</tr>
<tr>
<td>Amount of data</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the inputs / as DP master / overall</li>
</ul>
</td>
<td>7808 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the outputs / as DP master / overall</li>
</ul>
</td>
<td>7808 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the inputs / per DP slave</li>
</ul>
</td>
<td>244 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the outputs / per DP slave</li>
</ul>
</td>
<td>244 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the diagnostic data / per DP slave</li>
</ul>
</td>
<td>244 byte</td>
</tr>
<tr>
<td>Service / as DP slave</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>DPV0</li>
</ul>
</td>
<td>Yes</td>
</tr>
<tr>
<td>
<ul>
<li>DPV1</li>
</ul>
</td>
<td>No</td>
</tr>
<tr>
<td>Amount of data</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the inputs / as DP slave / overall</li>
</ul>
</td>
<td>122 byte</td>
</tr>
<tr>
<td>
<ul>
<li>of the address area of the outputs / as DP slave / overall</li>
</ul>
</td>
<td>122 byte</td>
</tr>
<tr>
<td>Number of possible connections / for S7/PG communication / maximum</td>
<td>8</td>
</tr>
<tr>
<td>Number of configurable connections / per PC station</td>
<td>207</td>
</tr>
<tr>
<td>Configuration software / required</td>
<td>NCM PC is included in scope of delivery of the required software product</td>
</tr>
<tr>
<td>Product function / Port diagnostics</td>
<td>Yes</td>
</tr>
<tr>
<td>Standards, specifications, approvals</td>
<td></td>
</tr>
<tr>
<td>Standard</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>for EMC</li>
</ul>
</td>
<td>2004/108/EC</td>
</tr>
<tr>
<td>
<ul>
<li>for safety / of CSA and UL</li>
</ul>
</td>
<td>CAN/CSA C22.2 &amp; UL 60950-1</td>
</tr>
<tr>
<td>
<ul>
<li>for emitted interference</li>
</ul>
</td>
<td>EN 61000-6-3, EN 61000-6-4</td>
</tr>
<tr>
<td>
<ul>
<li>for interference immunity</li>
</ul>
</td>
<td>EN 61000-6-1, EN 61000-6-2</td>
</tr>
<tr>
<td>Verification of suitability</td>
<td></td>
</tr>
<tr>
<td>
<ul>
<li>CE mark</li>
</ul>
</td>
<td>Yes</td>
</tr>
<tr>
<td>
<ul>
<li>C-Tick</li>
</ul>
</td>
<td>Yes</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>https://www.profibus-connector.com/usb-mpi-cables/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
		<item>
		<title>SIEMENS USB S7-300 MPI adapter</title>
		<link>https://www.profibus-connector.com/siemens-usb-s7-300-mpi-adapter/</link>
		<comments>https://www.profibus-connector.com/siemens-usb-s7-300-mpi-adapter/#comments</comments>
		<pubDate>Sat, 20 Apr 2013 04:29:05 +0000</pubDate>
		<dc:creator>nancy</dc:creator>
				<category><![CDATA[Promotion for Siemens products]]></category>
		<category><![CDATA[SIEMENS USB S7-300 MPI adapter]]></category>

		<guid isPermaLink="false">http://localhost/?p=25172</guid>
		<description><![CDATA[Siemens S7-300 PLC need S7-300 adapter,or S7 PC adapter and Siemens PLC cable to design. 6ES7972-0CB20-0XA0 Image similar Image gallery (1) SIMATIC S7, PC ADAPTER USB F. CONNECTION OF S7-200/300/ 400, C7; WITH USB-CABLE (5M) CAN BE USED UNDER WINXP/VISTA/ [...]]]></description>
				<content:encoded><![CDATA[<p><strong>Siemens S7-300 PLC need S7-300 adapter,or S7 PC adapter and Siemens PLC cable to design.</strong></p>
<div>6ES7972-0CB20-0XA0</div>
<div>
<div>
<div><img alt="Product" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/P_ST70_XX_02066t.jpg" /></div>
<div>Image similar</div>
<div><a> Image gallery (1)</a></div>
</div>
<div>
<div>SIMATIC S7, PC ADAPTER USB F. CONNECTION OF S7-200/300/ 400, C7; WITH USB-CABLE (5M) CAN BE USED UNDER WINXP/VISTA/ WINDOWS 7 32/64BIT</div>
<div></div>
<div>We have a new adapter named USB-MPI+V2.0  &amp; USB-MPI+ V4.0, which can replace the Siemens adatper 6ES7972-0CB20-0XA0.</div>
<div><a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/usb-mpi-adapter-siemens-s7-300-400?tracking=nancy" target="_blank">USB-MPI +V2.0</a>, the price is only $90.00/pc, you can <a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/usb-mpi-adapter-siemens-s7-300-400?tracking=nancy" target="_blank">purchase it now.</a></div>
<div><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-MPI+-2.jpg"><img class="alignnone size-thumbnail wp-image-25201" alt="USB-MPI+-2" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-MPI+-2-e1366873634194-150x150.jpg" width="150" height="150" /></a></div>
<div><a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/USB-MPI-adapter-s7-200-s7-300-s7-400?tracking=nancy" target="_blank">USB-MPI+ V4.0</a>, the price is only $99.99/pc, you can<a href="http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/USB-MPI-adapter-s7-200-s7-300-s7-400?tracking=nancy" target="_blank"> purchase it now</a>.</div>
<div>Pls read our manual of USB-MPI+V4.0. <a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-MPI+-V4.02.pdf">USB-MPI+ V4.0</a></div>
<div><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-MPI+-V4.0.jpg"><img class="alignnone size-thumbnail wp-image-25202" alt="USB-MPI+ V4.0" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-MPI+-V4.0-150x150.jpg" width="150" height="150" /></a></div>
<div>Of course, we also have USB-MPI V5.0 &amp; V6.0：</div>
<div><a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-MPI-V5.0.jpg"><img class="alignnone size-thumbnail wp-image-25203" alt="USB-MPI V5.0" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/USB-MPI-V5.0-150x150.jpg" width="150" height="150" /></a>             <a href="http://www.profibus-connector.com/wp-content/uploads/2013/04/0CB20-1-V6.0.jpg"><img class="alignnone size-thumbnail wp-image-25204" alt="0CB20-1 V6.0" src="http://www.profibus-connector.com/wp-content/uploads/2013/04/0CB20-1-V6.0-150x150.jpg" width="150" height="150" /></a></div>
<div>For more details, or for wholesale purchase, pls feel free to contact me:</div>
<div><strong>Contact person:  Ms. Nancy</strong></div>
<div><strong>Skype: kollewin</strong></div>
<div><strong>E-mail: <a href="mailto:nancy@kollewin.com">nancy@kollewin.com</a></strong></div>
<div><strong>Tel: +86-0755-26898905-8005</strong></div>
<div><strong>Fax: +86-0755-26898905-8008</strong></div>
<div><strong>Website: <a href="http://www.kollewin.com">www.kollewin.com</a></strong></div>
<div>
<p>Optoelectronic isolated USB/MPI V2.0,Siemens S7-300/400 PLC Programming adapter cable,3 meters,with communication indicator,can replace Siemens 6ES7 972-0CB20-0XA0,automatically adjust the communication speed from 19.2Kbps to 115.2Kbps for the PC port,automatically adjust the communication speed from 19.2Kbps to 187.5Kbps for the MPI interface.It doesn&#8217;t support profibus function.</p>
<p>USB/MPI+ is the optoelectronic isolated adapter for industrial design. There is anti-surging&amp; anti-lightning protection circuit for the USB and RS485 interface. It support hot plug. It‘s suitable for the communication between Siemens S7-300/400 series PLC or other equipments with MPI interface and computer. In particular, it applies to the strong interfere industrial scene and the safeguard in the circuit guarantees the safely running of the system.</p>
<p>USB/MPI+ programming cable simulate USB port as traditional serial port (usually COM3), which enables existing programming software(STEP 7) to communicate through simulated traditional port and PLC devices.</p>
</div>
<div></div>
<div>The siemens adapter datasheet.</div>
<div></div>
</div>
</div>
<div>
<div>
<div>
<table>
<tbody>
<tr>
<td colspan="2">Product</td>
</tr>
<tr>
<td>Article Number (Market Facing Number)</td>
<td>6ES7972-0CB20-0XA0</td>
</tr>
<tr>
<td>Product Description</td>
<td>SIMATIC S7, PC ADAPTER USB F. CONNECTION OF S7-200/300/ 400, C7; WITH USB-CABLE (5M) CAN BE USED UNDER WINXP/VISTA/ WINDOWS 7 32/64BIT</td>
</tr>
<tr>
<td>Product family</td>
<td><a href="https://eb.automation.siemens.com/mall/en/WW/Catalog/Products/10098516?activeTab=product">CPU 314C-2 PN/DP</a></td>
</tr>
<tr>
<td>Product Lifecycle (PLM)</td>
<td>PM300:Active Product</td>
</tr>
<tr>
<td colspan="2">Price data</td>
</tr>
<tr>
<td>Price Group</td>
<td>261</td>
</tr>
<tr>
<td>List Price</td>
<td id="DetailsGridListPriceCell"><a href="https://eb.automation.siemens.com/registration/Login.aspx?lang=en&amp;app=GOOS&amp;ret=https%3a%2f%2feb.automation.siemens.com%2fmall%2fen%2fWW%2fCatalog%2fProduct%2f6ES7972-0CB20-0XA0&amp;login=&amp;pwd=">Show prices</a></td>
</tr>
<tr>
<td>Customer Price</td>
<td id="DetailsGridCustomerPriceCell"><a href="https://eb.automation.siemens.com/registration/Login.aspx?lang=en&amp;app=GOOS&amp;ret=https%3a%2f%2feb.automation.siemens.com%2fmall%2fen%2fWW%2fCatalog%2fProduct%2f6ES7972-0CB20-0XA0&amp;login=&amp;pwd=">Show prices</a></td>
</tr>
<tr>
<td>Surcharge for Raw Materials</td>
<td id="DetailsGridMetalSurchargeCell">None</td>
</tr>
<tr>
<td>Metal Factor</td>
<td>None</td>
</tr>
<tr>
<td colspan="2">Delivery information</td>
</tr>
<tr>
<td>Export Control Regulations</td>
<td>AL : N / ECCN : EAR99H</td>
</tr>
<tr>
<td>Delivery Time</td>
<td>1 Day/Days</td>
</tr>
<tr>
<td>Net Weight (kg)</td>
<td>0,493 Kg</td>
</tr>
<tr>
<td>Product Dimensions (W x L x H)</td>
<td>Not available</td>
</tr>
<tr>
<td>Packaging Dimension</td>
<td>17.40 x 24.30 x 4.30</td>
</tr>
<tr>
<td>Package size unit of measure</td>
<td>CM</td>
</tr>
<tr>
<td>Quantity Unit</td>
<td>Piece</td>
</tr>
<tr>
<td>Packaging Quantity</td>
<td>1</td>
</tr>
<tr>
<td colspan="2">Additional Product Information</td>
</tr>
<tr>
<td>EAN</td>
<td>4019169101325</td>
</tr>
<tr>
<td>UPC</td>
<td>Not available</td>
</tr>
<tr>
<td>Commodity Code</td>
<td>85176200</td>
</tr>
<tr>
<td>LKZ_FDB/ CatalogID</td>
<td>ST79</td>
</tr>
<tr>
<td>Product Group</td>
<td>4064</td>
</tr>
<tr>
<td>Country of origin</td>
<td>Germany</td>
</tr>
<tr>
<td>RoHs Compliance</td>
<td>RoHS compliant since: 05.11.2007</td>
</tr>
<tr>
<td>Product class</td>
<td>A: Standard product which is a stock item could be returned within the returns guidelines/period.</td>
</tr>
<tr>
<td>Obligation Category for taking back electrical and electronic equipment after use</td>
<td>No obligation to take back electrical and electronic equipment after use</td>
</tr>
<tr>
<td colspan="2">Classifications</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>https://www.profibus-connector.com/siemens-usb-s7-300-mpi-adapter/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
