<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Profibus Connector &#187; FX2N-485-BD</title>
	<atom:link href="https://www.profibus-connector.com/tag/fx2n-485-bd/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.profibus-connector.com</link>
	<description>Profibus DP, Profibus Cable, Profibus Repeater and PLC Automation</description>
	<lastBuildDate>Fri, 25 Oct 2013 08:50:10 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.5.1</generator>
		<item>
		<title>Mitsubishi FX2N-485-BD+ RS485 Board</title>
		<link>https://www.profibus-connector.com/mitsubishi-fx2n-485-bd-board-2/</link>
		<comments>https://www.profibus-connector.com/mitsubishi-fx2n-485-bd-board-2/#comments</comments>
		<pubDate>Thu, 22 Aug 2013 08:24:18 +0000</pubDate>
		<dc:creator>nancy</dc:creator>
				<category><![CDATA[Siemens S7-200]]></category>
		<category><![CDATA[Communication Board]]></category>
		<category><![CDATA[FX2N-485-BD]]></category>
		<category><![CDATA[Mitsubishi]]></category>
		<category><![CDATA[RS485]]></category>

		<guid isPermaLink="false">http://www.profibus-connector.com/?p=27025</guid>
		<description><![CDATA[Introduction to Mitsubishi FX2N-485-BD+ The communication board FX2N-485-BD for RS485 (hereinafter referred to as &#8220;485BD&#8221;) can be connected to the base unit of the FX2N Series programmable controller to be used for the following applications. 1) Data transfer using no [...]]]></description>
				<content:encoded><![CDATA[<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 22px;"><strong>Introduction to Mitsubishi FX2N-485-BD+</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">The communication board FX2N-485-BD for RS485 (hereinafter referred to as &ldquo;485BD&rdquo;) can be connected to the base unit of the FX2N Series programmable controller to be used for the following applications.</span><br />
	<span style="font-size: 16px;">1) Data transfer using no protocol<br />
	Data communication with diversified RS232C units including personal computers, bar code readers and printers can be performed via the RS485 (422) converter using the no protocol. In this application, data is sent or received using the data registers specified by the RS instruction. For the setting and program examples, refer to the FX Programming Manual and FX Communication User&rsquo;s Manual.<br />
	2) Data transfer using the dedicated protocol<br />
	Data transfer with RS485 (422) units can be performed on the 1:N basis using the dedicated protocol.<br />
	For the contents of the dedicated protocol used in this application, refer to the FX Communication User&rsquo;s Manual.<br />
	3) Data transfer using the parallel link<br />
	Data transfer with an FX2N programmable controller can be performed on the 1:1 basis for 100 auxiliary relays and 10 data registers. For the setting and program examples, refer to the FX Communication User&rsquo;s Manual.<br />
	4) Data transfer using the N:N network<br />
	Data transfer with FX2N programmable controllers can be performed on the N:N basis. For the setting,the number of transferred data and program examples, refer to the FX Communication User&rsquo;s Manual.</span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 18px;"><span style="color: rgb(0, 0, 0);"><strong>1.1 External Dimensions of Mitsubishi FX2N-485-BD+</strong></span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/121.jpg"><span style="color: rgb(0, 0, 0);"><img alt="12" class="alignnone size-full wp-image-26152" height="285" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/121.jpg" width="730" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 18px;"><span style="color: rgb(0, 0, 0);"><strong>1.2 System Configuration</strong> <strong>of Mitsubishi FX2N-485-BD+</strong></span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 18px;"><span style="color: rgb(0, 0, 0);"><strong>1.2.1 No Protocol or Dedicated Protocol of Mistubishi FX2N-485-BD+</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/131.jpg"><span style="color: rgb(0, 0, 0);"><img alt="13" class="alignnone size-full wp-image-26153" height="237" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/131.jpg" width="706" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>1.2.2 Parallel Link</strong></span> <span style="font-size: 16px;"><span style="font-size: 18px;"><strong>of Mistubishi FX2N-485-BD+</strong></span></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/141.jpg"><span style="color: rgb(0, 0, 0);"><img alt="14" class="alignnone size-full wp-image-26154" height="261" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/141.jpg" width="591" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>1.2.3 N:N Network of Mistubishi FX2N-485-BD+</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/151.jpg"><span style="color: rgb(0, 0, 0);"><img alt="15" class="alignnone size-full wp-image-26155" height="198" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/151.jpg" width="715" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>MUNTING AND WIRING</strong> <strong>of Mitsubishi FX2N-485-BD+</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 18px;"><span style="color: rgb(0, 0, 0);"><strong>2.1 Mounting Procedure</strong> <strong>to Mistubishi FX2N-485-BD+</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/162.jpg"><span style="color: rgb(0, 0, 0);"><img alt="16" class="alignnone size-full wp-image-26156" height="286" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/162.jpg" width="753" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 18px;"><span style="color: rgb(0, 0, 0);"><strong>2.2&nbsp; Cable and Terminal Resistor to connect the RS485 FX2N-485-BD+</strong></span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>2.2.1 Cable</strong> <strong>to connect Mistubishi FX2N-485-BD</strong></span>+<br />
	<span style="font-size: 16px;">To connect the RS485 (422) unit, use a shielded twisted-pair cable.<br />
	The cable specification must be AWG 26 to 16, and the maximum tightening torque must be 0.6 N&middot;m (6 kgf&middot;cm). If a cable other than the AWG 26 to 16 is used, normal communication cannot be assured because the terminal may be imperfectly contacted. It is recommended to insert a cable integrated by the crimping tool into the terminal.</span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;"><span style="font-size: 18px;"><strong>2.2.2 Terminal Resistor</strong></span> </span><span style="font-size: 18px;"><strong>of Mistubishi FX2N-485-BD</strong></span>+<br />
	<span style="font-size: 16px;">Provide the terminal resistor at both ends of the line as described in section 2.3.2 and 2.3.3.<br />
	1) In the case of two-pair wiring, connect the terminal resistor (330W, 1/4W) between terminals SDA and SDB as well as between terminals RDA and RDB.</span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/172.jpg"><span style="color: rgb(0, 0, 0);"><img alt="17" class="alignnone size-full wp-image-26158" height="126" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/172.jpg" width="234" /></span></a><br />
	<span style="color: rgb(0, 0, 0);">Use the resistors offered as accessories of the 485BD.<br />
	2) In the case of one-pair wiring, connect the terminal resistor (110W, 1/2W)between terminals RDA and RDB. Use the resistors offered as accessories of the 485BD.</span><br />
	<a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/181.jpg"><span style="color: rgb(0, 0, 0);"><img alt="18" class="alignnone size-full wp-image-26157" height="131" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/181.jpg" width="143" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 18px;"><span style="color: rgb(0, 0, 0);"><strong>2.3 Wiring of Mitsubishi FX2N-485-BD+</strong></span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>2.3.1 Selection of Wiring</strong> <strong>of Mistubishi FX2N-485-BD</strong></span>+<br />
	<span style="font-size: 16px;">Wiring of RS485 is one-pair wiring or two-pair wiring. The wiring method is decided according to the<br />
	usage. Please select the wiring method from the table below.</span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/192.jpg"><span style="color: rgb(0, 0, 0);"><img alt="19" class="alignnone size-full wp-image-26160" height="334" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/192.jpg" width="747" /></span></a></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">*1 When this product is added to the system, please match the wiring to the wiring method of the system.<br />
	*2 When using 485BD with, this wiring method remember to take account of/or ignore the &ldquo;echo&rdquo; of the commands sent from the FX2N programmable controller.<br />
	*3 Use FX2N programmable controller and 485BD together.<br />
	*4 For excluding the combination of 485BD, please see below.</span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/202.jpg"><span style="color: rgb(0, 0, 0);"><img alt="20" class="alignnone size-full wp-image-26161" height="204" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/202.jpg" width="744" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>2.3.2 Two-pair Wiring</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/213.jpg"><span style="color: rgb(0, 0, 0);"><img alt="21" class="alignnone size-full wp-image-26162" height="330" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/213.jpg" width="701" /></span></a></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">*1 R is the terminating resistance. Connect the terminating resistance (330W) between terminals SDA and SDB, and terminals RDA and RDB.<br />
	*2 The shield of the shielded twisted-pair cable must be connected to ground (100W or less). When using parallel link, ground both side. When using no protocol or dedicated protocol, ground one side.<br />
	*3 Connect terminal FG to each terminal of the programmable controller main body grounded with resistance of 100 or less. However, for the computer link unit of the A series programmable controller, see the manual of the computer link unit.<br />
	*4 When using RS232/485 or RS232/422 interface, please the use FX-485PC-IF.</span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>2.3.3 One-pair Wiring</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/221.jpg"><span style="color: rgb(0, 0, 0);"><img alt="22" class="alignnone size-full wp-image-26163" height="338" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/221.jpg" width="719" /></span></a></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">*1 R is the terminating resistance. Connect the terminating resistance (110W) between terminals RDA and RDB.<br />
	*2 The shield of the shielded twisted-pair cable must be connected to ground (100W or less). When using parallel link, ground both side. When using no protocol or dedicated protocol, ground one side.<br />
	*3 Connect terminal FG to each terminal of the programmable controller main body grounded with resistance of 100 or less. However, for the computer link unit of the A series programmable controller, see the manual of the computer link unit.<br />
	*4 When using RS232/485 or RS232/422 interface, please the use FX-485PC-IF.</span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>SPECIFICATIONS of Mitsubishi FX2N-485-BD+</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>3.1 General Specifications of Mitsubishi FX2N-485-BD</strong></span>+<br />
	<span style="font-size: 16px;">General specifications are the same as those for the FX2N series programmable controller.</span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>3.2 Power Supply Specification of Mitsubishi FX2N-485-BD</strong></span>+<br />
	<span style="font-size: 16px;">5V DC, 60 mA is supplied from the programmable controller.</span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>3.3 Specification</strong> <strong>of Mitsubishi FX2N-485-BD</strong></span></span></span>+
</p>
<table border="0" cellpadding="0" cellspacing="0" width="497">
<colgroup>
<col />
<col />
	</colgroup>
<tbody>
<tr height="19">
<td height="19" style="height:19px;width:223px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;Item &nbsp;</span></span></span>
			</td>
<td style="width:275px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;Content &nbsp;</span></span></span>
			</td>
</tr>
<tr height="19">
<td height="19" style="height:19px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;Transmission standard &nbsp;</span></span></span>
			</td>
<td>
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;Conforming to RS485 and RS422 &nbsp;</span></span></span>
			</td>
</tr>
<tr height="19">
<td height="19" style="height:19px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;Transmission distance &nbsp;</span></span></span>
			</td>
<td>
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;Max. 50 m &nbsp;</span></span></span>
			</td>
</tr>
<tr height="19">
<td height="19" style="height:19px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;LED indicators &nbsp;</span></span></span>
			</td>
<td>
<p>
					<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;SD, RD &nbsp;</span></span></span>
				</p>
</td>
</tr>
</tbody>
</table>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;</span></span></span>
</p>
<table border="0" cellpadding="0" cellspacing="0" height="239" width="579">
<colgroup>
<col />
<col />
<col />
	</colgroup>
<tbody>
<tr height="19">
<td colspan="2" height="19" style="height:19px;width:313px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Item</span></span></span>
			</td>
<td style="width:441px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Content</span></span></span>
			</td>
</tr>
<tr height="27">
<td height="103" rowspan="4" style="height:103px;width:131px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Communication<br />
				method<br />
				and protocol</span></span></span>
			</td>
<td>
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">N:N network</span></span></span>
			</td>
<td rowspan="3">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Half-duplex communication</span></span></span>
			</td>
</tr>
<tr height="38">
<td height="38" style="height:38px;width:183px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Dedicated protocol<br />
				(format 1 or format 4)</span></span></span>
			</td>
</tr>
<tr height="19">
<td height="19" style="height:19px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Parallel link</span></span></span>
			</td>
</tr>
<tr height="19">
<td height="19" style="height:19px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">No protocol</span></span></span>
			</td>
<td>
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Full-duplex communication</span></span></span>
			</td>
</tr>
<tr height="76">
<td colspan="2" height="76" style="height:76px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Supported baud rate</span></span></span>
			</td>
<td style="width:441px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Dedicated protocol and no protocol: 300 ~ 19,200 (bps)<br />
				Parallel link : 19,200 (bps)<br />
				N:N network : 38,400 (bps)</span></span></span>
			</td>
</tr>
<tr height="19">
<td colspan="2" height="19" style="height:19px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Isolation</span></span></span>
			</td>
<td>
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">No isolation</span></span></span>
			</td>
</tr>
</tbody>
</table>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>DIAGNOSTICS</strong> <strong>of Mitsubishi FX2N-485-BD+</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">For error code of N:N network and computer link, refer to the FX Communication User&rsquo;s Manual.</span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;"><span style="font-size: 22px;"><strong>4.1 Common Items</strong></span><br />
	1) Check the connection with the communication unit of the programmable controller and the wiring.<br />
	When the connection is unstable, the communication can not be corrected.<br />
	2) Check whether the VRRD or VRSC instruction is used in used in the program.<br />
	If it is used, delete it, turn off the power of the programmable controller, then turn it on again.<br />
	3) Each setting of communication format (D8120), parameter of programmable controller by FX-PCS/WIN-E, N:N network (D8173 to D8180) and parallel link (M8070, M8071) is suitable for the usage or it checks. The communication is not correctly done if setting is not suitable for the usage.<br />
	When each setting is changed, please turn off the power supply of the programmable controller, and turn it on again.<br />
	4) When you use FX0N-485ADP or FX-485ADP in network, please the power supply for the drive must be supplied correctly or check.</span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>4.2 LED Check Items of Mitsubishi FX2N-485-BD</strong></span>+<br />
	<span style="font-size: 16px;"><strong><span style="font-size: 18px;">4.2.1 N:N Network</span></strong><br />
	1) Check the status of the RD LED and the SD LED provided on each 485BD.<br />
	- If both of them are lit and extinguished, nothing is wrong.<br />
	- If the RD LED is lit/extinguished but the SD LED is not lit/extinguished (not lit at all), check the setting of the station No.,the baud rate (transmission rate) and the total number of salve stations.<br />
	- If the RD LED is not lit/extinguished, check the wiring.<br />
	2) Make sure that the communication error (FX2N: M8183 to M8190, FX0N: M504 to M511) in each slave station is not turned on and that the data communication flag (FX2N: M8191, FX0N: M503) is not turned off. When one of the communication error flag is turned on or if the data communication flag is turned off, check the error code of data registers (FX2N: D8211 to D8218, FX0N: D211 to D218). </span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">For the error code, please see the FX Communication User&rsquo;s Manual.&nbsp;</span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;"><span style="font-size: 18px;"><strong>4.3 Parallel Link</strong></span><br />
	1) Check the status of the RD(RXD) LED and the SD(TXD) LED provided on each communication unit.<br />
	- If both of them are lit and extinguished, nothing is wrong.<br />
	- If the RD(RXD) LED is lit/extinguished but the SD(TXD) LED is not lit/extinguished (not lit at all),check the setting of the master station and the slave stations.<br />
	- If the RD(RXD) LED is not lit/extinguished, check the wiring.<br />
	2) Make sure that the master station and the slave stations are set correctly. If the setting is incorrect,correct it.<br />
	3) Make sure that the devices for the master station and the slave stations are handled correctly. If they are handled incorrectly, correct the program so that they are handled correctly.</span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;"><span style="font-size: 18px;"><strong>4.4 Computer Link</strong></span><br />
	1) Check the status of the RD(RXD) LED and the SD(TXD) LED provided on each communication unit.<br />
	- If both of them are lit and extinguished, nothing is wrong.<br />
	- If the RD(RXD) LED is lit/extinguished but the SD(TXD) LED is not lit/extinguished (not lit at all),check the setting of the station No. and the transmission rate (baud rate).<br />
	- If the RD(RXD) LED is not lit/extinguished, check the wiring and confirm the connection with the programmable controller.<br />
	2) Make sure that the communication procedure is performed correctly. If it is not performed correctly,correct the setting in the computer.<br />
	3) Check the NAK error code and programmable controller error code.<br />
	For the error code, please see the FX Communication User&rsquo;s Manual.</span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;"><span style="font-size: 18px;"><strong>4.5 RS Instruction</strong></span><br />
	1) Check the status of the RD (RXD) LED and the SD (TXD) LED provided in an optional equipment.<br />
	- If the RD (RXD) LED is not lit while data is received or the SD (TXD) LED is not lit while data is sent, check the installation and the wiring.<br />
	- When the RD (RXD) LED is lit while data is received or the SD (TXD) LED is lit while data is sent, the installation and the wiring are correct.<br />
	2) Make sure the timing of data send/receive. For example, make sure that the counterpart equipment is ready for receive before starting to send data to it.<br />
	3) When the terminator is not used, check whether the send data capacity is equivalent to the acceptable data capacity. If the send data capacity may be changed, use the terminator.<br />
	4) Make sure that the external equipment is correctly operating.<br />
	5) Check whether the type of send data and the type of receive data are equivalent. If they are different,make them equivalent.<br />
	6) When two or more RS instructions are used in the program, make sure that only one RS instruction is actuated in one operation cycle. Never turn off the RS instruction while data is received or sent.<br />
	7) In the FX2N Series (V2.00 or later), an RS instruction is not executed if the counterpart equipment receives &ldquo;NAK&rdquo;.<br />
	Arrange the system so that the RS instruction is executed even if the counterpart equipment receives &ldquo;NAK&rdquo;.</span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>Our company (Kollewin Technology CO., Limited) have new products.</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>Named FX2N-485-BD+ .</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>They are 100% compatible with Mitsubishi original FX2N-485-BD.</strong></span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>Part#:</strong></span><a href="http://www.automation-world.com/FX2N-485-BD-plus?filter_name=FX2N-485-BD?tracking=nancy"><span style="color: rgb(0, 0, 0);"><strong>FX2N-485-BD+</strong></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>The unit price is USD62.89/pc</strong> </span><a href="http://www.automation-world.com/FX2N-485-BD-plus?filter_name=FX2N-485-BD?tracking=nancy"><span style="color: rgb(0, 0, 0);"><img alt="buy buttom" class="alignnone size-full wp-image-25316" height="36" src="http://www.profibus-connector.com/wp-content/uploads/2013/05/buy-buttom2.jpg" width="100" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>USER&#39;S MUNUAL PDF of communication board FX2N-485-BD</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><strong><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-485-BD-USERS-MANUAL.pdf"><span style="color: rgb(0, 0, 255);">FX2N-485-BD-USER&#39;S MANUAL</span></a></strong></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-485-BD1.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX2N-485-BD" class="alignnone size-full wp-image-26166" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-485-BD1.jpg" width="665" /></span></a></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-485-BD+.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX2N-485-BD+" class="alignnone size-full wp-image-26139" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-485-BD+.jpg" width="665" /></span></a></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><span style="border-collapse: separate; font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: normal; orphans: 2; text-indent: 0px; text-transform: none; white-space: normal; widows: 2; word-spacing: 0px;"><span style="text-align: left;"><b id="mainContent">Specification <strong>of</strong></b></span></span><strong> communication board FX2N-485-BD+</strong><span style="border-collapse: separate; font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: normal; orphans: 2; text-indent: 0px; text-transform: none; white-space: normal; widows: 2; word-spacing: 0px;"><span style="text-align: left;"><b>:</b></span></span></span></span></span>
</p>
<table border="0" cellpadding="0" cellspacing="0" width="515">
<colgroup>
<col />
<col />
	</colgroup>
<tbody>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Product Name</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Communication Board</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Fit</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">for Mitsubishi FX2N PLC</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Model NO.</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">FX2N-485-BD</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Interface</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Conforming to RS485 and RS422</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Connector Type</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Mini Din 8 Pin</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Voltage</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">DC 5V</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Current</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">60mA</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Max.Transmission Distance</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">50M</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">LED Indicators</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">SD, RD</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Communication Method</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Half-duplex</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Insulation</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">No Insulated</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Material</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Plastic, Metal</span></span></span>
			</td>
</tr>
</tbody>
</table>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>Description of communication board FX2N-485-BD+:</strong></span></span></span>
</p>
<ul>
<li>
		<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><strong><span style="font-size: 16px;">FX2N are suitable for use with FX2N PLC&#39;s. FX2N-232-BD are used for RS-485 applications, such as communication with a PC, printer or bar code reader. and provide a second programming port which enables an operator panel (or HMI) and a programming panel to be connected to the PLC at the same time.</span></strong></span></span>
	</li>
<li>
		<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;"><strong>This is a Replacement of Mitsubishi FX2N-485-BD Programmable Controller.</strong></span></span></span>
	</li>
<li>
		<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(255, 0, 0);"><span style="font-size: 16px;"><b>This is OEM product, not Mitsubishi original part.</b></span></span></span>
	</li>
</ul>
<p>
	&nbsp;
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<span style="padding: 0px; margin: 0px; line-height: 14px; font-family: 'trebuchet ms', helvetica, sans-serif; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 0); "><strong style="padding: 0px; margin: 0px; "><span style="padding: 0px; margin: 0px; line-height: 16px; font-size: 16px; "><span style="padding: 0px; margin: 0px; line-height: 22px; font-size: 22px; ">More communication boards we have</span></span></strong></span></span>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx2n-485-bd-board-2/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX2N-485-BD+</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx2n-485-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX2N-485-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx2n-422-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX2N-422-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx2n-232-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX2N-232-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx1n-485-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX1N-485-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx1n-422-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX1N-422-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx3u-485-bd-rs485-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX3U-485-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx3u-422-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX3U-422-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx3u-232-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX3U-232-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx3u-usb-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX3U-USB-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; font-family: 'trebuchet ms', helvetica, sans-serif; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/fx2n-4da-module-mitsubish/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); ">FX2N-4DA</span></a></span></strong>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>More pictures of PLC communication board</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX1N-USB-BD-1.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX1N-USB-BD-1" class="alignnone size-full wp-image-26145" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX1N-USB-BD-1.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-USB-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX3U-USB-BD" class="alignnone size-full wp-image-26144" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-USB-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-CNV-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX3U-CNV-BD" class="alignnone size-full wp-image-26143" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-CNV-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-485-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX3U-485-BD" class="alignnone size-full wp-image-26142" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-485-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-422-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX3U-422-BD" class="alignnone size-full wp-image-26141" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-422-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-232-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX3U-232-BD" class="alignnone size-full wp-image-26140" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-232-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-422-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX2N-422-BD" class="alignnone size-full wp-image-26131" height="925" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-422-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-USB-BD-1.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX2N-USB-BD-1" class="alignnone size-full wp-image-26133" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-USB-BD-1.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX1N-422-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX1N-422-BD" class="alignnone size-full wp-image-26135" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX1N-422-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX1N-485-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX1N-485-BD" class="alignnone size-full wp-image-26136" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX1N-485-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-232-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX2N-232-BD" class="alignnone size-full wp-image-26137" height="925" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-232-BD.jpg" width="665" /></span></a></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 22px;"><strong>Please feel free to contact me for any question!</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 22px;"><strong>Contact person: Miss Nancy</strong></span></span></span>
</p>
<div>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>Skype: kollewin</strong></span><br />
	<strong><span style="color: rgb(0, 0, 0);">E-mail: </span><a href="mailto:nancy@kollewin.com"><span style="color: rgb(0, 0, 0);">nancy@kollewin.com</span></a></strong><br />
	<span style="color: rgb(0, 0, 0);"><strong>Tel: +86-0755-26898905-8006</strong></span><br />
	<strong><span style="color: rgb(0, 0, 0);">Website: </span><a href="http://www.kollewin.com"><span style="color: rgb(0, 0, 0);">www.kollewin.com</span></a></strong></span></span>
</div>
]]></content:encoded>
			<wfw:commentRss>https://www.profibus-connector.com/mitsubishi-fx2n-485-bd-board-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Mitsubishi FX2N-485-BD RS485 Board</title>
		<link>https://www.profibus-connector.com/mitsubishi-fx2n-485-bd-board/</link>
		<comments>https://www.profibus-connector.com/mitsubishi-fx2n-485-bd-board/#comments</comments>
		<pubDate>Sat, 29 Jun 2013 08:00:06 +0000</pubDate>
		<dc:creator>nancy</dc:creator>
				<category><![CDATA[Mitsubishi PLC Communication Board]]></category>
		<category><![CDATA[Communication Board]]></category>
		<category><![CDATA[FX2N-485-BD]]></category>
		<category><![CDATA[Mitsubishi FX2N]]></category>
		<category><![CDATA[RS485 interface]]></category>

		<guid isPermaLink="false">http://www.profibus-connector.com/?p=26151</guid>
		<description><![CDATA[Introduction to Mitsubishi FX2N-485-BD The communication board FX2N-485-BD for RS485 (hereinafter referred to as &#8220;485BD&#8221;) can be connected to the base unit of the FX2N Series programmable controller to be used for the following applications. 1) Data transfer using no [...]]]></description>
				<content:encoded><![CDATA[<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 22px;"><strong>Introduction to Mitsubishi FX2N-485-BD</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">The communication board FX2N-485-BD for RS485 (hereinafter referred to as &ldquo;485BD&rdquo;) can be connected to the base unit of the FX2N Series programmable controller to be used for the following applications.</span><br />
	<span style="font-size: 16px;">1) Data transfer using no protocol<br />
	Data communication with diversified RS232C units including personal computers, bar code readers and printers can be performed via the RS485 (422) converter using the no protocol. In this application, data is sent or received using the data registers specified by the RS instruction. For the setting and program examples, refer to the FX Programming Manual and FX Communication User&rsquo;s Manual.<br />
	2) Data transfer using the dedicated protocol<br />
	Data transfer with RS485 (422) units can be performed on the 1:N basis using the dedicated protocol.<br />
	For the contents of the dedicated protocol used in this application, refer to the FX Communication User&rsquo;s Manual.<br />
	3) Data transfer using the parallel link<br />
	Data transfer with an FX2N programmable controller can be performed on the 1:1 basis for 100 auxiliary relays and 10 data registers. For the setting and program examples, refer to the FX Communication User&rsquo;s Manual.<br />
	4) Data transfer using the N:N network<br />
	Data transfer with FX2N programmable controllers can be performed on the N:N basis. For the setting,the number of transferred data and program examples, refer to the FX Communication User&rsquo;s Manual.</span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 18px;"><span style="color: rgb(0, 0, 0);"><strong>1.1 External Dimensions of Mitsubishi FX2N-485-BD</strong></span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/121.jpg"><span style="color: rgb(0, 0, 0);"><img alt="12" class="alignnone size-full wp-image-26152" height="285" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/121.jpg" width="730" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 18px;"><span style="color: rgb(0, 0, 0);"><strong>1.2 System Configuration</strong> <strong>of Mitsubishi FX2N-485-BD</strong></span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 18px;"><span style="color: rgb(0, 0, 0);"><strong>1.2.1 No Protocol or Dedicated Protocol of Mistubishi FX2N-485-BD</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/131.jpg"><span style="color: rgb(0, 0, 0);"><img alt="13" class="alignnone size-full wp-image-26153" height="237" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/131.jpg" width="706" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>1.2.2 Parallel Link</strong></span> <span style="font-size: 16px;"><span style="font-size: 18px;"><strong>of Mistubishi FX2N-485-BD</strong></span></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/141.jpg"><span style="color: rgb(0, 0, 0);"><img alt="14" class="alignnone size-full wp-image-26154" height="261" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/141.jpg" width="591" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>1.2.3 N:N Network of Mistubishi FX2N-485-BD</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/151.jpg"><span style="color: rgb(0, 0, 0);"><img alt="15" class="alignnone size-full wp-image-26155" height="198" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/151.jpg" width="715" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>MUNTING AND WIRING</strong> <strong>of Mitsubishi FX2N-485-BD</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 18px;"><span style="color: rgb(0, 0, 0);"><strong>2.1 Mounting Procedure</strong> <strong>to Mistubishi FX2N-485-BD</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/162.jpg"><span style="color: rgb(0, 0, 0);"><img alt="16" class="alignnone size-full wp-image-26156" height="286" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/162.jpg" width="753" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 18px;"><span style="color: rgb(0, 0, 0);"><strong>2.2&nbsp; Cable and Terminal Resistor to connect the RS485 FX2N-485-BD</strong></span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>2.2.1 Cable</strong> <strong>to connect Mistubishi FX2N-485-BD</strong></span><br />
	<span style="font-size: 16px;">To connect the RS485 (422) unit, use a shielded twisted-pair cable.<br />
	The cable specification must be AWG 26 to 16, and the maximum tightening torque must be 0.6 N&middot;m (6 kgf&middot;cm). If a cable other than the AWG 26 to 16 is used, normal communication cannot be assured because the terminal may be imperfectly contacted. It is recommended to insert a cable integrated by the crimping tool into the terminal.</span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;"><span style="font-size: 18px;"><strong>2.2.2 Terminal Resistor</strong></span> </span><span style="font-size: 18px;"><strong>of Mistubishi FX2N-485-BD</strong></span><br />
	<span style="font-size: 16px;">Provide the terminal resistor at both ends of the line as described in section 2.3.2 and 2.3.3.<br />
	1) In the case of two-pair wiring, connect the terminal resistor (330W, 1/4W) between terminals SDA and SDB as well as between terminals RDA and RDB.</span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/172.jpg"><span style="color: rgb(0, 0, 0);"><img alt="17" class="alignnone size-full wp-image-26158" height="126" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/172.jpg" width="234" /></span></a><br />
	<span style="color: rgb(0, 0, 0);">Use the resistors offered as accessories of the 485BD.<br />
	2) In the case of one-pair wiring, connect the terminal resistor (110W, 1/2W)between terminals RDA and RDB. Use the resistors offered as accessories of the 485BD.</span><br />
	<a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/181.jpg"><span style="color: rgb(0, 0, 0);"><img alt="18" class="alignnone size-full wp-image-26157" height="131" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/181.jpg" width="143" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 18px;"><span style="color: rgb(0, 0, 0);"><strong>2.3 Wiring of Mitsubishi FX2N-485-BD</strong></span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>2.3.1 Selection of Wiring</strong> <strong>of Mistubishi FX2N-485-BD</strong></span><br />
	<span style="font-size: 16px;">Wiring of RS485 is one-pair wiring or two-pair wiring. The wiring method is decided according to the<br />
	usage. Please select the wiring method from the table below.</span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/192.jpg"><span style="color: rgb(0, 0, 0);"><img alt="19" class="alignnone size-full wp-image-26160" height="334" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/192.jpg" width="747" /></span></a></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">*1 When this product is added to the system, please match the wiring to the wiring method of the system.<br />
	*2 When using 485BD with, this wiring method remember to take account of/or ignore the &ldquo;echo&rdquo; of the commands sent from the FX2N programmable controller.<br />
	*3 Use FX2N programmable controller and 485BD together.<br />
	*4 For excluding the combination of 485BD, please see below.</span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/202.jpg"><span style="color: rgb(0, 0, 0);"><img alt="20" class="alignnone size-full wp-image-26161" height="204" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/202.jpg" width="744" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>2.3.2 Two-pair Wiring</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/213.jpg"><span style="color: rgb(0, 0, 0);"><img alt="21" class="alignnone size-full wp-image-26162" height="330" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/213.jpg" width="701" /></span></a></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">*1 R is the terminating resistance. Connect the terminating resistance (330W) between terminals SDA and SDB, and terminals RDA and RDB.<br />
	*2 The shield of the shielded twisted-pair cable must be connected to ground (100W or less). When using parallel link, ground both side. When using no protocol or dedicated protocol, ground one side.<br />
	*3 Connect terminal FG to each terminal of the programmable controller main body grounded with resistance of 100 or less. However, for the computer link unit of the A series programmable controller, see the manual of the computer link unit.<br />
	*4 When using RS232/485 or RS232/422 interface, please the use FX-485PC-IF.</span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>2.3.3 One-pair Wiring</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 16px;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/221.jpg"><span style="color: rgb(0, 0, 0);"><img alt="22" class="alignnone size-full wp-image-26163" height="338" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/221.jpg" width="719" /></span></a></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">*1 R is the terminating resistance. Connect the terminating resistance (110W) between terminals RDA and RDB.<br />
	*2 The shield of the shielded twisted-pair cable must be connected to ground (100W or less). When using parallel link, ground both side. When using no protocol or dedicated protocol, ground one side.<br />
	*3 Connect terminal FG to each terminal of the programmable controller main body grounded with resistance of 100 or less. However, for the computer link unit of the A series programmable controller, see the manual of the computer link unit.<br />
	*4 When using RS232/485 or RS232/422 interface, please the use FX-485PC-IF.</span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>SPECIFICATIONS of Mitsubishi FX2N-485-BD</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>3.1 General Specifications of Mitsubishi FX2N-485-BD</strong></span><br />
	<span style="font-size: 16px;">General specifications are the same as those for the FX2N series programmable controller.</span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>3.2 Power Supply Specification of Mitsubishi FX2N-485-BD</strong></span><br />
	<span style="font-size: 16px;">5V DC, 60 mA is supplied from the programmable controller.</span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>3.3 Specification</strong> <strong>of Mitsubishi FX2N-485-BD</strong></span></span></span>
</p>
<table border="0" cellpadding="0" cellspacing="0" width="497">
<colgroup>
<col />
<col />
	</colgroup>
<tbody>
<tr height="19">
<td height="19" style="height:19px;width:223px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;Item &nbsp;</span></span></span>
			</td>
<td style="width:275px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;Content &nbsp;</span></span></span>
			</td>
</tr>
<tr height="19">
<td height="19" style="height:19px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;Transmission standard &nbsp;</span></span></span>
			</td>
<td>
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;Conforming to RS485 and RS422 &nbsp;</span></span></span>
			</td>
</tr>
<tr height="19">
<td height="19" style="height:19px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;Transmission distance &nbsp;</span></span></span>
			</td>
<td>
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;Max. 50 m &nbsp;</span></span></span>
			</td>
</tr>
<tr height="19">
<td height="19" style="height:19px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;LED indicators &nbsp;</span></span></span>
			</td>
<td>
<p>
					<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;SD, RD &nbsp;</span></span></span>
				</p>
</td>
</tr>
</tbody>
</table>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">&nbsp;</span></span></span>
</p>
<table border="0" cellpadding="0" cellspacing="0" height="239" width="579">
<colgroup>
<col />
<col />
<col />
	</colgroup>
<tbody>
<tr height="19">
<td colspan="2" height="19" style="height:19px;width:313px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Item</span></span></span>
			</td>
<td style="width:441px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Content</span></span></span>
			</td>
</tr>
<tr height="27">
<td height="103" rowspan="4" style="height:103px;width:131px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Communication<br />
				method<br />
				and protocol</span></span></span>
			</td>
<td>
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">N:N network</span></span></span>
			</td>
<td rowspan="3">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Half-duplex communication</span></span></span>
			</td>
</tr>
<tr height="38">
<td height="38" style="height:38px;width:183px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Dedicated protocol<br />
				(format 1 or format 4)</span></span></span>
			</td>
</tr>
<tr height="19">
<td height="19" style="height:19px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Parallel link</span></span></span>
			</td>
</tr>
<tr height="19">
<td height="19" style="height:19px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">No protocol</span></span></span>
			</td>
<td>
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Full-duplex communication</span></span></span>
			</td>
</tr>
<tr height="76">
<td colspan="2" height="76" style="height:76px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Supported baud rate</span></span></span>
			</td>
<td style="width:441px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Dedicated protocol and no protocol: 300 ~ 19,200 (bps)<br />
				Parallel link : 19,200 (bps)<br />
				N:N network : 38,400 (bps)</span></span></span>
			</td>
</tr>
<tr height="19">
<td colspan="2" height="19" style="height:19px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Isolation</span></span></span>
			</td>
<td>
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">No isolation</span></span></span>
			</td>
</tr>
</tbody>
</table>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>DIAGNOSTICS</strong> <strong>of Mitsubishi FX2N-485-BD</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">For error code of N:N network and computer link, refer to the FX Communication User&rsquo;s Manual.</span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;"><span style="font-size: 22px;"><strong>4.1 Common Items</strong></span><br />
	1) Check the connection with the communication unit of the programmable controller and the wiring.<br />
	When the connection is unstable, the communication can not be corrected.<br />
	2) Check whether the VRRD or VRSC instruction is used in used in the program.<br />
	If it is used, delete it, turn off the power of the programmable controller, then turn it on again.<br />
	3) Each setting of communication format (D8120), parameter of programmable controller by FX-PCS/WIN-E, N:N network (D8173 to D8180) and parallel link (M8070, M8071) is suitable for the usage or it checks. The communication is not correctly done if setting is not suitable for the usage.<br />
	When each setting is changed, please turn off the power supply of the programmable controller, and turn it on again.<br />
	4) When you use FX0N-485ADP or FX-485ADP in network, please the power supply for the drive must be supplied correctly or check.</span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 18px;"><strong>4.2 LED Check Items of Mitsubishi FX2N-485-BD</strong></span><br />
	<span style="font-size: 16px;"><strong><span style="font-size: 18px;">4.2.1 N:N Network</span></strong><br />
	1) Check the status of the RD LED and the SD LED provided on each 485BD.<br />
	- If both of them are lit and extinguished, nothing is wrong.<br />
	- If the RD LED is lit/extinguished but the SD LED is not lit/extinguished (not lit at all), check the setting of the station No.,the baud rate (transmission rate) and the total number of salve stations.<br />
	- If the RD LED is not lit/extinguished, check the wiring.<br />
	2) Make sure that the communication error (FX2N: M8183 to M8190, FX0N: M504 to M511) in each slave station is not turned on and that the data communication flag (FX2N: M8191, FX0N: M503) is not turned off. When one of the communication error flag is turned on or if the data communication flag is turned off, check the error code of data registers (FX2N: D8211 to D8218, FX0N: D211 to D218). </span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">For the error code, please see the FX Communication User&rsquo;s Manual.&nbsp;</span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;"><span style="font-size: 18px;"><strong>4.3 Parallel Link</strong></span><br />
	1) Check the status of the RD(RXD) LED and the SD(TXD) LED provided on each communication unit.<br />
	- If both of them are lit and extinguished, nothing is wrong.<br />
	- If the RD(RXD) LED is lit/extinguished but the SD(TXD) LED is not lit/extinguished (not lit at all),check the setting of the master station and the slave stations.<br />
	- If the RD(RXD) LED is not lit/extinguished, check the wiring.<br />
	2) Make sure that the master station and the slave stations are set correctly. If the setting is incorrect,correct it.<br />
	3) Make sure that the devices for the master station and the slave stations are handled correctly. If they are handled incorrectly, correct the program so that they are handled correctly.</span></span></span>
</p>
<p>
	<br />
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;"><span style="font-size: 18px;"><strong>4.4 Computer Link</strong></span><br />
	1) Check the status of the RD(RXD) LED and the SD(TXD) LED provided on each communication unit.<br />
	- If both of them are lit and extinguished, nothing is wrong.<br />
	- If the RD(RXD) LED is lit/extinguished but the SD(TXD) LED is not lit/extinguished (not lit at all),check the setting of the station No. and the transmission rate (baud rate).<br />
	- If the RD(RXD) LED is not lit/extinguished, check the wiring and confirm the connection with the programmable controller.<br />
	2) Make sure that the communication procedure is performed correctly. If it is not performed correctly,correct the setting in the computer.<br />
	3) Check the NAK error code and programmable controller error code.<br />
	For the error code, please see the FX Communication User&rsquo;s Manual.</span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;"><span style="font-size: 18px;"><strong>4.5 RS Instruction</strong></span><br />
	1) Check the status of the RD (RXD) LED and the SD (TXD) LED provided in an optional equipment.<br />
	- If the RD (RXD) LED is not lit while data is received or the SD (TXD) LED is not lit while data is sent, check the installation and the wiring.<br />
	- When the RD (RXD) LED is lit while data is received or the SD (TXD) LED is lit while data is sent, the installation and the wiring are correct.<br />
	2) Make sure the timing of data send/receive. For example, make sure that the counterpart equipment is ready for receive before starting to send data to it.<br />
	3) When the terminator is not used, check whether the send data capacity is equivalent to the acceptable data capacity. If the send data capacity may be changed, use the terminator.<br />
	4) Make sure that the external equipment is correctly operating.<br />
	5) Check whether the type of send data and the type of receive data are equivalent. If they are different,make them equivalent.<br />
	6) When two or more RS instructions are used in the program, make sure that only one RS instruction is actuated in one operation cycle. Never turn off the RS instruction while data is received or sent.<br />
	7) In the FX2N Series (V2.00 or later), an RS instruction is not executed if the counterpart equipment receives &ldquo;NAK&rdquo;.<br />
	Arrange the system so that the RS instruction is executed even if the counterpart equipment receives &ldquo;NAK&rdquo;.</span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>Our company (Kollewin Technology CO., Limited) have new products.</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>Named FX2N-485-BD &amp;&nbsp;FX2N-485-BD+ .</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>They are 100% compatible with Mitsubishi original FX2N-485-BD.</strong></span></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>Part#: </strong></span><a href="http://www.automation-world.com/FX2N-485-BD?filter_name=FX2N-485-BD?tracking=nancy"><span style="color: rgb(0, 0, 0);"><strong>FX2N-485-BD</strong></span></a></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>The unit price is USD21.00/pc</strong>&nbsp; </span><a href="http://www.automation-world.com/FX2N-485-BD?filter_name=FX2N-485-BD?tracking=nancy"><span style="color: rgb(0, 0, 0);"><img alt="buy buttom" class="alignnone size-full wp-image-25316" height="36" src="http://www.profibus-connector.com/wp-content/uploads/2013/05/buy-buttom2.jpg" width="100" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>Part#:</strong></span><a href="http://www.automation-world.com/FX2N-485-BD-plus?filter_name=FX2N-485-BD?tracking=nancy"><span style="color: rgb(0, 0, 0);"><strong>FX2N-485-BD+</strong></span></a></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>The unit price is USD62.89/pc</strong> </span><a href="http://www.automation-world.com/FX2N-485-BD-plus?filter_name=FX2N-485-BD?tracking=nancy"><span style="color: rgb(0, 0, 0);"><img alt="buy buttom" class="alignnone size-full wp-image-25316" height="36" src="http://www.profibus-connector.com/wp-content/uploads/2013/05/buy-buttom2.jpg" width="100" /></span></a></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>USER&#39;S MUNUAL PDF of communication board FX2N-485-BD</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><strong><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-485-BD-USERS-MANUAL.pdf"><span style="color: rgb(0, 0, 255);">FX2N-485-BD-USER&#39;S MANUAL</span></a></strong></span></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-485-BD1.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX2N-485-BD" class="alignnone size-full wp-image-26166" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-485-BD1.jpg" width="665" /></span></a></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-485-BD+.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX2N-485-BD+" class="alignnone size-full wp-image-26139" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-485-BD+.jpg" width="665" /></span></a></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><span style="border-collapse: separate; font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: normal; orphans: 2; text-indent: 0px; text-transform: none; white-space: normal; widows: 2; word-spacing: 0px;"><span style="text-align: left;"><b id="mainContent">Specification <strong>of</strong></b></span></span><strong> communication board FX2N-485-BD</strong><span style="border-collapse: separate; font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: normal; orphans: 2; text-indent: 0px; text-transform: none; white-space: normal; widows: 2; word-spacing: 0px;"><span style="text-align: left;"><b>:</b></span></span></span></span></span>
</p>
<table border="0" cellpadding="0" cellspacing="0" width="515">
<colgroup>
<col />
<col />
	</colgroup>
<tbody>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Product Name</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Communication Board</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Fit</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">for Mitsubishi FX2N PLC</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Model NO.</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">FX2N-485-BD</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Interface</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Conforming to RS485 and RS422</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Connector Type</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Mini Din 8 Pin</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Voltage</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">DC 5V</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Current</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">60mA</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Max.Transmission Distance</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">50M</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">LED Indicators</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">SD, RD</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Communication Method</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Half-duplex</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Insulation</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">No Insulated</span></span></span>
			</td>
</tr>
<tr height="22">
<td height="22" style="height:22px;width:225px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Material</span></span></span>
			</td>
<td style="width:291px;">
				<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;">Plastic, Metal</span></span></span>
			</td>
</tr>
</tbody>
</table>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>Description of communication board FX2N-485-BD:</strong></span></span></span>
</p>
<ul>
<li>
		<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><strong><span style="font-size: 16px;">FX2N are suitable for use with FX2N PLC&#39;s. FX2N-232-BD are used for RS-485 applications, such as communication with a PC, printer or bar code reader. and provide a second programming port which enables an operator panel (or HMI) and a programming panel to be connected to the PLC at the same time.</span></strong></span></span>
	</li>
<li>
		<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 16px;"><strong>This is a Replacement of Mitsubishi FX2N-485-BD Programmable Controller.</strong></span></span></span>
	</li>
<li>
		<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(255, 0, 0);"><span style="font-size: 16px;"><b>This is OEM product, not Mitsubishi original part.</b></span></span></span>
	</li>
</ul>
<p>
	&nbsp;
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<span style="padding: 0px; margin: 0px; line-height: 14px; font-family: 'trebuchet ms', helvetica, sans-serif; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 0); "><strong style="padding: 0px; margin: 0px; "><span style="padding: 0px; margin: 0px; line-height: 16px; font-size: 16px; "><span style="padding: 0px; margin: 0px; line-height: 22px; font-size: 22px; ">More communication boards, please click below links:</span></span></strong></span></span>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx2n-485-bd-board-2/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX2N-485-BD+</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx2n-485-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX2N-485-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx2n-422-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX2N-422-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx2n-232-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX2N-232-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx1n-485-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX1N-485-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx1n-422-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX1N-422-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx3u-485-bd-rs485-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX3U-485-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx3u-422-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX3U-422-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx3u-232-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX3U-232-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/mitsubishi-fx3u-usb-bd-board/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); "><span style="padding: 0px; margin: 0px; font-family: 'trebuchet ms', helvetica, sans-serif; ">FX3U-USB-BD</span></span></a></span></strong>
</p>
<p style="padding: 0px; margin: 0px 0px 10px; line-height: 20px; clear: both; color: rgb(85, 85, 85); font-family: Lato, sans-serif; font-size: 14px; ">
	<strong style="padding: 0px; margin: 0px; line-height: 14px; font-family: 'trebuchet ms', helvetica, sans-serif; "><span style="padding: 0px; margin: 0px; line-height: 20px; font-size: 20px; "><a href="http://www.profibus-connector.com/fx2n-4da-module-mitsubish/" style="padding: 0px; margin: 0px; color: rgb(119, 119, 119); text-decoration: none; "><span style="padding: 0px; margin: 0px; color: rgb(0, 0, 255); ">FX2N-4DA</span></a></span></strong>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>More pictures of PLC communication board&nbsp;</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX1N-USB-BD-1.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX1N-USB-BD-1" class="alignnone size-full wp-image-26145" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX1N-USB-BD-1.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-USB-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX3U-USB-BD" class="alignnone size-full wp-image-26144" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-USB-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-CNV-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX3U-CNV-BD" class="alignnone size-full wp-image-26143" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-CNV-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-485-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX3U-485-BD" class="alignnone size-full wp-image-26142" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-485-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-422-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX3U-422-BD" class="alignnone size-full wp-image-26141" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-422-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-232-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX3U-232-BD" class="alignnone size-full wp-image-26140" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX3U-232-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-422-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX2N-422-BD" class="alignnone size-full wp-image-26131" height="925" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-422-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-USB-BD-1.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX2N-USB-BD-1" class="alignnone size-full wp-image-26133" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-USB-BD-1.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX1N-422-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX1N-422-BD" class="alignnone size-full wp-image-26135" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX1N-422-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX1N-485-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX1N-485-BD" class="alignnone size-full wp-image-26136" height="665" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX1N-485-BD.jpg" width="665" /></span></a><span style="color: rgb(0, 0, 0);"> </span><a href="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-232-BD.jpg"><span style="color: rgb(0, 0, 0);"><img alt="FX2N-232-BD" class="alignnone size-full wp-image-26137" height="925" src="http://www.profibus-connector.com/wp-content/uploads/2013/06/FX2N-232-BD.jpg" width="665" /></span></a></span>
</p>
<p>
	&nbsp;
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 22px;"><strong>Please feel free to contact me for any question!</strong></span></span></span>
</p>
<p>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="color: rgb(0, 0, 0);"><span style="font-size: 22px;"><strong>Contact person: Miss Nancy</strong></span></span></span>
</p>
<div>
	<span style="font-family:trebuchet ms,helvetica,sans-serif;"><span style="font-size: 22px;"><span style="color: rgb(0, 0, 0);"><strong>Skype: kollewin</strong></span><br />
	<strong><span style="color: rgb(0, 0, 0);">E-mail: </span><a href="mailto:nancy@kollewin.com"><span style="color: rgb(0, 0, 0);">nancy@kollewin.com</span></a></strong><br />
	<span style="color: rgb(0, 0, 0);"><strong>Tel: +86-0755-26898905-8006</strong></span><br />
	<strong><span style="color: rgb(0, 0, 0);">Website: </span><a href="http://www.kollewin.com"><span style="color: rgb(0, 0, 0);">www.kollewin.com</span></a></strong></span></span>
</div>
]]></content:encoded>
			<wfw:commentRss>https://www.profibus-connector.com/mitsubishi-fx2n-485-bd-board/feed/</wfw:commentRss>
		<slash:comments>6</slash:comments>
		</item>